Skip to main content

Table 1 Results of 4-field-tables

From: Accuracy of cardiovascular magnetic resonance in myocarditis: comparison of MR and histological findings in an animal model

 

Sensitivity

Specificity

positive predictive value

negative predictive value

Turbo-FLASH-examination with fat saturation

left anterior

61.54%

81.82%

80.0%

64.29%

left lateral

69.23%

72.73%

75.0%

66.67%

left inferior

0%

73.68%

0.0%

73.68%

septum

25.0%

80.0%

20.0%

84.21%

Turbo-FLASH-examination without fat saturation

left anterior

61.54%

81.82%

80.0%

64.29%

left lateral

76.92%

72.73%

76.92%

72.73%

left inferior

20.0%

66.67%

12.5%

77.78%

septum

0.0%

75.0%

0%

78.95%

TSE-examination with fat saturation

left anterior

30.77%

81.82%

66.67%

50.0%

left lateral

50.0%

90.91%

85.71%

62.5%

left inferior

0%

100.0%

0

79.17%

septum

0%

90.0%

0

81.82%

TSE-examination without fat saturation

left anterior

25.0%

90.91%

75.0%

52.63%

left lateral

15.38%

72.73%

40.0%

42.11%

left inferior

0%

100%

0%

79.17%

septum

25.0%

90%

33.33%

85.71%

  1. Results of 4-field-tables for LGE detected by different CMR-sequences.