Iron overload measurements by CMR in patients with suspected hemochromatosis - comparison of methods for T2* calculation in myocardium and liver

Introduction

Iron tissue overload can be detected non-invasively by CMR using T2* measurements techniques. Hemochromatosis is a disorder of iron metabolism that results in excess iron accumulation in tissues and organs. If left undiagnosed and untreated, iron overload can cause serious, sometimes fatal health problems. Early detection of iron overload and hemochromatosis treatment can prevent complications and prolong life.

Purpose

Our objective was to investigate T2* measurements in patients with suspected hemochromatosis and to compare different approaches on T2* calculation for the myocardium and liver.

Methods

We evaluated 42 consecutive patients with suspected hemochromatosis using CMR in a 1.5 T GE HDx scanner. We performed breath-hold fast GRE sequence on a short-axis view (including liver tissue in the same image) with several in-phase TEs(from 27.6 to 4.2 ms) and fixed TR of 31 ms to calculate T2* for the liver and myocardium using both, the entire signal intensity (SI) curve (T2* = 1/exp) and only 2 points (9.6 and 4.2 ms) with the following equation: -((9.6-4.2)/LN(SI @9.6/SI@4.2)). We will call them curve and formula T2* calculations, respectively. For the liver iron overload we also used the technique described by Rennes University, described in detail elsewhere http://www.radio.univ-rennes1.fr/Sources/EN/HemoTech.html.

Results

From the 42 patients with suspected hemochromatosis, 14 had a mutation of HFE gene detected (more commonly heterozygosis of C282Y or H63D). Mean serum ferritin level was 745.9 ± 364.8 μg/L (Nl < 300 for men and < 200 for women). Mean myocardial T2* was 32.1 ± 10.0 and 29.5 ± 11.3 ms for curve and formula calculations, respectively (p = 0.04). Mean liver T2* was 15.5 ± 6.8 and 15.2 ± 8.1 for curve and formula calculations, respectively (p = 0.41). Both methods correlated well for myocardium (r = 0.74, p < 0.001) and for liver (r = 0.94, p < 0.001). For myocardium a better correlation was seen for the T2* < 20 ms (r = 0.87, p < 0.001).

Bland-Altman analysis showed T2* mean difference of 2.6(CI 0.1-5.0) and 0.4 ms (CI -0.6-1.3) for myocardium and liver comparisons, respectively, between curve and formula calculations. Most of cases had mild liver iron overload by Rennes method, with mean T2* of 15.4 ± 5.7 and maximal T2* of 31.5 ms (below the normal value of 35 ms), indicating good agreement.

Conclusion

Measurements of T2* in patients with suspected hemochromatosis could detect all ranges of myocardial and liver iron overload, and thus contributing to clinical management. The different approaches of myocardial and liver T2* calculations led to similar results, indicating that they could be used interchangeably. The 2 point formula approach could be a faster option for T2* image acquisition and calculation.

Author information

Authors and Affiliations

Authors

Rights and permissions

Open Access This article is published under license to BioMed Central Ltd. This is an Open Access article is distributed under the terms of the Creative Commons Attribution 2.0 International License (https://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Rochitte, C.E., Sara, L., Shiozaki, A.A. et al. Iron overload measurements by CMR in patients with suspected hemochromatosis - comparison of methods for T2* calculation in myocardium and liver. J Cardiovasc Magn Reson 12 (Suppl 1), P285 (2010). https://doi.org/10.1186/1532-429X-12-S1-P285

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/1532-429X-12-S1-P285

Keywords