Table 2 Cardiac functional parameters for each method, infarcted mice n = 5.

From: Accelerating global left-ventricular function assessment in mice using reduced slice acquisition and three-dimensional guide-point modelling

 

Std

GPM Full

GPM

Six Slice

GPM

Four Slice

Std-GPM

Full

Std-GPM

Six Slice

Std-GPM

Four Slice

LV mass [mg]

113 ± 10

116 ± 11

117 ± 11

135 ± 18

2.8 ± 4.3

3.4 ± 2.3

22 ± 10*

EDV [μl]

162 ± 20

158 ± 22

160 ± 23

162 ± 22

-3.6 ± 6.8

-2.0 ± 5.7

-0.3 ± 7.1

ESV [μl]

131 ± 20

129 ± 23

131 ± 21

135 ± 22

-1.1 ± 2.5

0.4 ± 4.2

4.5 ± 4.8+

SV [μl]

31 ± 6

29 ± 5

29 ± 5

27 ± 3

-2.5 ± 5.4

-1.3 ± 2.1

-4.8 ± 2.8

EF [%]

20 ± 4

19 ± 4

18 ± 3

17 ± 3

-1.1 ± 2.5

-2.4 ± 3.7

-2.9 ± 1.3*