From: Assessment of distribution and evolution of Mechanical dyssynchrony in a porcine model of myocardial infarction by cardiovascular magnetic resonance
Normal
Peri-Infarct
Infarct
p value
Peak eC Early
-24 ± 4
-18 ± 2
-6 ± 2
< 0.0001
TTP Early
329 ± 40
332 ± 36
440 ± 40
0.0002*
Peak eC Late
-21 ± 2
-17 ± 1
-8 ± 2
TTP Late
321 ± 40
355 ± 61
442 ± 63
0.0054*