Skip to main content

Quantitative assessment of myocardial blood flow in coronary artery disease by cardiovascular magnetic resonance: comparison of Fermi and distributed parameter modeling against invasive methods

Abstract

Background

Mathematical modeling of perfusion cardiovascular magnetic resonance (CMR) data allows absolute quantification of myocardial blood flow and can potentially improve the diagnosis and prognostication of obstructive coronary artery disease (CAD), against the current clinical standard of visual assessments. This study compares the diagnostic performance of distributed parameter modeling (DP) against the standard Fermi model, for the detection of obstructive CAD, in per vessel against per patient analysis.

Methods

A pilot cohort of 28 subjects (24 included in the final analysis) with known or suspected CAD underwent adenosine stress-rest perfusion CMR at 3T. Data were analysed using Fermi and DP modeling against invasive coronary angiography and fractional flow reserve, acquired in all subjects. Obstructive CAD was defined as luminal stenosis of ≥70 % alone, or luminal stenosis ≥50 % and fractional flow reserve ≤0.80.

Results

On ROC analysis, DP modeling outperformed the standard Fermi model, in per vessel and per patient analysis. In per patient analysis, DP modeling-derived myocardial blood flow at stress demonstrated the highest sensitivity and specificity (0.96, 0.92) in detecting obstructive CAD, against Fermi modeling (0.78, 0.88) and visual assessments (0.79, 0.88), respectively.

Conclusions

DP modeling demonstrated consistently increased diagnostic performance against Fermi modeling and showed that it may have merit for stratifying patients with at least one vessel with obstructive CAD.

Trial Registration

Clinical Trial Registration: Clinicaltrials.gov NCT01368237

Registered 6 of June 2011. URL: https://clinicaltrials.gov/ct2/show/NCT01368237

Background

Perfusion cardiovascular magnetic resonance (CMR) is a technique that allows the non-invasive assessment of coronary artery disease (CAD) [1, 2]. Clinically, the current standard method of assessment of perfusion CMR is based either on visual estimates of the images, or on a semi-quantitative assessment of perfusion index [3, 4]. Visual assessments of areas of abnormal perfusion rely on the presence of myocardial areas with normal perfusion for direct comparison. Visual estimates are particularly difficult in multi-vessel disease where there may be minimal areas of normal perfusion to compare against, or in cases of severe left ventricular impairment [5] in which slow bolus dispersion leads to low contrast enhancement globally within the myocardium. Mathematical modeling of perfusion imaging data allows absolute quantification of myocardial blood flow (MBF) and it may be particularly useful in cases in which visual assessment is compromised. By quantifying perfusion, it also has the potential to minimize interobserver variability and to improve the diagnosis and prognostication of CAD [5, 6].

Fermi deconvolution modeling is an empirical-mathematical model used to estimate MBF from perfusion CMR data during first-pass of gadolinium-based extracellular contrast agents [7]. Distributed parameter (DP) deconvolution modeling is based upon physiological principles of tracer kinetics analysis and it can provide MBF quantification and additional information about coronary vascularity and permeability [8]. This includes estimates of intravascular space, extravascular-extracellular space, permeability surface area product, extraction fraction and volume of distribution.

Fermi modeling is currently the most popular approach for quantitative analysis of perfusion CMR data [5]. The diagnostic performance of Fermi modeling in detecting obstructive CAD has been assessed, with variable conclusions whether it provides additive clinical information to visual assessment [9] or not [5, 10]. In contrast to Fermi modeling, the diagnostic performance of DP modeling has not at this point been assessed against invasive clinical standard methods. In addition, there is still a disagreement whether Fermi modeling can provide haemodynamic thresholds either in per vessel [5, 10] or in per patient [11] basis, for robust patient stratification in the presence of obstructive CAD. A model comparison in per vessel against per patient analysis has not been fully assessed yet in a single CMR study.

The objective of this study was two-fold. Firstly, to investigate whether either Fermi or DP modeling may be more accurate in detecting reduced MBF in obstructive CAD, when compared against the current invasive clinical standard assessment of invasive coronary angiography and fractional flow reserve in a pilot population. The second objective of this study was to assess the diagnostic performance of both models in per vessel against per patient based analysis in this pilot population.

Methods

Study population and design

28 patients with history of stable angina and with known or suspected CAD were recruited for perfusion CMR. Exclusion criteria for all subjects included history of severely compromised renal function (Glomerular filtration rate ≤ 30  mL/min), pregnancy and contraindications to CMR. The study was performed with the approval of the institutional research ethics committee, in accordance with the Declaration of Helsinki and with the written informed consent of all subjects. All subjects were instructed to abstain from caffeine for 12 h before CMR. All patients underwent invasive coronary angiography and fractional flow reserve.

Cardiac magnetic resonance imaging

Perfusion CMR was acquired using a 3T Verio imaging system (Siemens, Healthcare Gmbh, Erlangen, Germany) using electrocardiogram-gating, as previously described [12]. Standard cardiac imaging planes and a short axis stack of left ventricular cine data were acquired using routine steady state free precession (TrueFISP) acquisitions. T1 MOLLI maps were acquired using the Siemens Works in Progress Package #448, Quantitative Cardiac Parameter Mapping [13]. Stress imaging was performed by intravenously administering 140 μg/kg/min of adenosine (Adenoscan, Sanofi Aventis) for 4 min and confirmation of patient symptoms. Fifty dynamic perfusion images were obtained at diastole across three short-axis view slices, covering 16 of the standard myocardial segments [14]. A turbo-fast low angle shot saturation recovery prepared single-shot gradient echo pulse sequence was used with imaging parameters: repetition time/ echo time 2.20 ms/1.07 ms, flip angle 12o, slice thickness 8 mm, preparation pulse delay to central line of k-space 100 ms, matrix size 192 × 108 and FoV 330 mm x 440 mm. With the application of GRAPPA (accelerator factor of 3) and partial Fourier acquisition of 0.75, each dynamic frame consisted of 48-phase encoding lines.

An intravenous bolus of 0.05 mmol/kg of a gadolinium-based contrast agent (Gadovist, Bayer Healthcare) was injected at 4 mL/s using an MR-compatible pump injector (Spectris Solaris, Medrad, Bayer). To allow clearance of residual contrast agent, rest perfusion imaging was performed 15 min after the adenosine-stress scan by repeating the same acquisition protocol in all subjects.

Invasive coronary angiography and fractional flow reserve

All patients underwent invasive coronary angiography and fractional flow reserve at the Royal Infirmary of Edinburgh. Fractional flow reserve was assessed for major epicardial vessels and defined as the ratio between distal coronary pressure and aortic pressure measured simultaneously at maximal adenosine-induced (intravenous 140 μg/kg/min) hyperaemia [15, 16]. Haemodynamically significant (obstructive) CAD was defined as luminal stenosis ≥70 % on invasive coronary angiography, or fractional flow reserve <0.80 and luminal stenosis ≥50 %. Outcomes from the three main coronary vessels were classified into 2 groups: Group 1, (no, minor or non)-obstructive CAD with luminal stenosis <50 % or with luminal stenosis ≥50 % and fractional flow reserve > 0.80; Group 2, obstructive CAD with luminal stenosis of ≥70 % alone, or luminal stenosis ≥50 % and fractional flow reserve ≤0.80 [15, 16].

Visual analysis

Perfusion CMR images were analyzed by 2 experienced observers blinded to all other data. The perfusion CMR scans were reported for the three main epicardial vessel territories and classified as positive for obstructive CAD in the presence of a stress-induced perfusion defect which was transmural and/or involved ≥ 1 myocardial segment, corresponding to the maximum sensitivity and specificity [10]. In the event of disagreement, the images were reviewed together and a consensus was reached.

Quantitative CMR analysis

Endocardial and epicardial MR contours were outlined using dedicated cardiac image analysis software (QMass, Medis, The Netherlands) to generate a standardised 16-segment American Heart Association (AHA) model of the heart (reference marker for myocardial segmentation was placed in the anteroseptal conjunction of the left and right ventricle) [14]. Quantification of MBF was performed using customised in-house software developed in Matlab (MathWorks Inc., Natick, MA), as previously described [12]. Myocardial and arterial input function signal intensity-time curves were converted to gadolinium concentration-time curves using the method of Larsson et al (see details in Additional file 1) [17]. Model-dependent deconvolution analysis was implemented to measure MBF using Fermi and 1-barrier 2-region DP functions as previously described (see details and functions in Additional file 2) [12]. To account for the delay time between the onset of contrast enhancement in the arterial input function and the myocardium, both models were fitted to the data multiple times, from zero to six times the temporal resolution at dynamic perfusion acquisition. The delay time reaching the optimal x2 fit to the data was used in the analysis [11, 12]. In DP modeling, additional microvascular characteristics were also calculated (Additional file 3). Myocardial perfusion reserve (MPR) was calculated by dividing the hyperemic MBF by the resting flow. The mean myocardial perfusion reserve of the two lowest scoring myocardial segments (MPR2) was also calculated for each vessel territory and its accuracy in detecting obstructive CAD was examined [5, 10]. Both models were applied to each of the 16 AHA segments. MBF, MPR and MPR2 were then averaged per epicardial vessel territory (vessel territories corresponded to the three main coronary vessels, also defined according to the 16 segment AHA model [14]). Mean values for MBF at stress, MPR and MPR2 were classified accordingly for per vessel and per patient based analysis (see classification in the results section referring to visual MR analysis).

Statistical analysis

Dedicated software were used for statistical analysis (R Foundation for statistical computing, Vienna, Austria, Analyse-it, Analyse-it Software, Leeds, England). Receiver-operating characteristic (ROC) analysis was used to determine threshold values for absolute MBF at stress, MPR and MPR2 with the greatest sensitivity and specificity to detect obstructive CAD (Group 2 versus Group 1). The maximal Youden Index was used to determine the optimal threshold values [5, 10]. The area under the curve (AUC) was calculated using trapezoidal numerical integration and a Delong et al nonparametric comparison was used to compare the diagnostic performance of quantitative methods [18]. Bland Altman plots were used to investigate systematic bias between Fermi and DP modeling values for MBF, MPR and MPR2.

An interobserver reliability analysis was performed for visual estimates using Cohen kappa statistic. Statistical differences in MBF values and in myocardial perfusion ratios between patient Groups (Group 2 against Group 1), were investigated by implementing a two sample t-test. Statistical significance was defined as two-sided P value < 0.05.

Results

Patients

The baseline demographics of the patient cohort are presented in Table 1. In the final analysis, data from 24 patients were used. Quantitative perfusion analysis was performed in 72 vessel territories in total. 3 patients did not complete the imaging session due to claustrophobia. 1 patient was excluded from the analysis due to electrocardiographic failures which caused considerable through plane motion.

Table 1 Baseline demographics

All patients underwent invasive coronary angiography and fractional flow reserve assessment. 16 patients (67 %) had at least 1 vessel territory classified with obstructive CAD (Group 2). 10 patients had 1-vessel disease, 2 had 2-vessel disease and 4 had 3-vessel disease.

Visual CMR analysis

The interobserver variability was kappa = 0.81 (95 % CI: 0.73 to 0.89). In per vessel analysis, vessel classification occurred using the cut off criteria described in the methods section for invasive assessments. In per patient analysis, patients with all vessel territories identified with (no, minor or non)- obstructive CAD were classified in Group 1, whilst patients with at least one vessel detected with obstructive CAD, were classified in Group 2. Based on these criteria (applied for both visual and quantitative CMR analysis), diagnostic performance (i.e. sensitivity, specificity, positive predictive value and negative predictive value) in per vessel and per patient visual MR analysis against invasive methods, are presented in Table 2. Examples of MR perfusion images are presented in Fig. 1.

Table 2 Diagnostic performance of visual CMR estimates
Fig. 1
figure 1

Perfusion CMR images from a patient with minor CAD (a, b, c) and a patient with (1-vessel) right coronary artery disease (d, e, f). White arrows show perfusion defect in the inferior and inferoseptal myocardial regions. Basal (a, d), mid-ventricular (b, e) and apical slices (c, f) are shown

Quantitative CMR analysis

Initially, quantitative MBF analysis was performed on a per vessel basis. Examples of arterial input function and model fitting for both models are shown in Fig. 2. Mean values for all Fermi- and DP modeling-derived haemodynamic parameters (i.e. absolute MBF at stress, MPR and MPR2), for both Groups 1 and 2, are presented in Table 3.

Fig. 2
figure 2

Arterial input functions and model fits on myocardial tissue curves from a patient with minor (a, b, c) and a patient with 1-vessel (d, e, f) CAD. a, d, b, e, c, f show arterial input functions, Fermi modeling and distributed parameter modeling fits, respectively. Gd: gadolinium

Table 3 Mean (SD) values for MBF at stress, MPR and MPR2, for Groups 1 and 2

Table 4 demonstrates results for each model. Significant differences in haemodynamic parameter values between Groups 1 and 2 were considerably higher for DP modeling, compared to Fermi modeling (Table 4). No differences were observed for blood flow values at rest between Groups 1 and 2, for both models. Significant differences were observed in all DP modeling-derived microvascular characteristics, between Groups 1 and 2 (all P ≤0.01). Mean values for microvascular characteristics are also presented (Additional file 4).

Table 4 Results from t-test and ROC analysis in per vessel and per patient based analysis

Systematic bias between Fermi- and DP modeling-derived values was investigated using Bland Altman plots (Additional file 5). The average bias was calculated as the Fermi modeling-derived estimates minus the DP modeling-derived estimates across all three haemodynamic parameters. For MBF at stress, MPR and MPR2, the average bias (95 % CI) was 0.55 (-0.51, 1.62), 0.38 (-0.54, 1.31), 0.25 (0.51, 1.00), respectively.

ROC analysis graphs are illustrated in Fig. 3. Haemodynamic thresholds defined on ROC analysis (Table 4) as compared to mean values for MBF at stress are illustrated in Fig. 4a. The AUC for MPR2 was significantly higher compared to both MBF at stress and MPR for Fermi modeling (Table 4). There were no significant differences between ROC curves across all three haemodynamic parameters for DP modeling (Table 4).

Fig. 3
figure 3

ROC curves presenting diagnostic performance for both models in per vessel analysis with (a), (b) and (c) showing measures of myocardial blood flow at stress, myocardial perfusion reserve and myocardial perfusion reserve of the two lowest scoring segments, respectively

Fig. 4
figure 4

Mean myocardial blood flow values (SD) at stress in per vessel (a) and per patient (b) analysis. Mean values and thresholds for Fermi and distributed parameter modeling are represented with red diamond, red square dot line and blue triangle, blue dash dot line, respectively. MBF: myocardial blood flow

Table 5 shows comparisons on ROC analysis between Fermi and DP modeling across all three haemodynamic parameters. Significant differences were observed in AUC between Fermi and DP modeling, except for the case of MPR2 (Table 5). The diagnostic performance was consistently higher for DP modeling, compared to Fermi modeling (Table 6).

Table 5 Results from ROC analysis for all Fermi versus DP modeling comparisons
Table 6 Diagnostic performance of Fermi and DP modeling in per vessel and per patient analysis

Following per vessel analysis, quantitative MBF analysis was investigated on a per patient basis. Mean values for all three Fermi- and DP modeling-derived haemodynamic parameters for Groups 1 and 2 are presented in Table 3.

Significant differences in haemodynamic parameter values between Groups 1 and 2 increased further for both models, with DP modeling demonstrating consistently greater differences, compared to Fermi modeling (Table 4).

Haemodynamic thresholds on ROC analysis and mean values for MBF at stress in per patient analysis are demonstrated in Fig. 4b. The AUC were generally increased in per patient analysis, in comparison with per vessel analysis (Table 4). No significant differences were observed in ROC curves between haemodynamic parameters for either model, in per patient analysis (Table 4).

The AUC were significantly superior for DP modeling, compared to Fermi modeling ( Fig. 5, Table 5). The diagnostic performance of both models was increased in per patient analysis compared against per vessel analysis, with DP modeling outperforming Fermi modeling across all three haemodynamic parameters (Table 6).

Fig. 5
figure 5

ROC curves demonstrating diagnostic performance for both models in per patient analysis with (a), (b) and (c) showing measures of myocardial blood flow at stress, myocardial perfusion reserve and myocardial perfusion reserve of the two lowest scoring segments, respectively

Discussion

The main findings of this study demonstrated that DP modeling outperformed the standard Fermi modeling in the setting of obstructive CAD detection, in both per vessel and per patient analysis. When compared with visual and quantitative CMR analysis, DP modeling-derived MBF at stress in per patient analysis, showed the highest diagnostic performance for the detection of obstructive CAD in our pilot population.

Visual versus quantitative CMR analysis

The interobserver variability for visual analysis was similar to a previously published value [10] and higher compared to another study [9]. In per vessel based analysis, visual CMR estimates gave higher specificity compared to quantitative CMR estimates (Tables 2 versus 6). However, quantitative CMR analysis showed superior sensitivity using both Fermi and DP modeling-derived MBF at stress, compared to visual CMR assessments.

In per patient based analysis, DP modeling demonstrated superior diagnostic performance in detecting obstructive CAD, compared to visual CMR estimates (Tables 2 versus 6).

Distributed parameter versus Fermi analysis

This is the first study assessing the diagnostic performance of 1-barrier 2-region DP modeling in 24 patients with known or suspected CAD, against invasive methods. Studies assessing the diagnostic performance of fully quantitative perfusion CMR methods in patients have mainly focused on the use of Fermi modeling [5, 9, 10, 19], or on a model-independent approach [20], for detecting obstructive CAD. A recent perfusion CMR study has assessed four different model applications (Fermi model, uptake model, one-compartmental model, model-independent approach) at 1.5T, in which it was shown that the diagnostic performance of quantitative MR analysis did not significantly differ between modeling methods, for obstructive CAD detection [11]. In our data analysis, the diagnostic power of Fermi modeling was in agreement with previously published studies [5, 911, 19]. However, DP modeling showed significantly higher diagnostic performance compared to Fermi modeling, which was consistent throughout both per vessel and per patient based analysis.

To date, no other perfusion CMR study has accurately identified perfusion abnormalities in the presence of significant CAD using only MBF value at stress as a measure (estimated per epicardial vessel territory). Perfusion CMR studies have instead defined the use of the lowest scoring segments for detecting obstructive CAD. This approach was applied either by using MPR as measure [5, 10, 19], or MBF at stress as measure [20], or both [11]. Patel et al. used Fermi modeling-derived MPR, to assess quantitative MR analysis in patients with obstructive CAD [9]. In our data, no differences were observed between all three haemodynamic parameters for either model, other than the case of the Fermi modeling derived-MPR2, which showed improvement against MBF at stress and MPR, in per vessel analysis. This agrees with previous studies demonstrating no difference between MBF at stress and MPR when the measure of the lowest scoring segments was examined [11, 20].

The optimal thresholds in per vessel (1.75 mL/min/mL) and in per patient (2.00 mL/min/mL) analysis for DP modeling-derived MBF at stress (Table 4), were in agreement with a previous positron emission tomography (PET) myocardial perfusion study (1.85 mL/min/mL) which aimed to localise perfusion defects to significantly stenotic coronary arteries in per vessel and per patient basis (≥70 % on invasive angiograms) [21]. It is important to note that PET is currently considered the reference standard for absolute non-invasive quantification of MBF [1, 5, 21].

The Fermi model demonstrated higher haemodynamic thresholds in both per vessel (2.49 mL/min/mL) and per patient (2.60 mL/min/mL) based analysis, compared to DP modeling (Table 4). Threshold values for Fermi modeling were in agreement with a previously published value (2.30 mL/min/mL) [22]. However, thresholds for Fermi modeling were in a slightly higher range compared to other PET perfusion studies (1.86, 2.50 and 2.45 mL/min/mL) [2325] respectively, which aimed to identify perfusion abnormalities against lower angiographic thresholds (≥50 % on invasive angiograms). In our analysis, higher perfusion estimates were observed for Fermi modeling compared to DP modeling, across all three haemodynamic parameters (Table 3, Bland Altman plot analysis). In the same context, other perfusion studies demonstrated that the Fermi model estimates MBF values that were systematically increased compared to DP modeling [12, 26], to two-compartmental modeling, model-independent and Patlak model analysis [27], as well as against PET imaging data analysed with the Patlak model [5]. It is known that arterial input function saturation effects that may be present in single bolus data can result in significant overestimation of MBF in Fermi modeling [28]. Our group has previously demonstrated that the DP model can be less dependent on arterial input function saturation effects, compared to the Fermi model [12]. Any MBF overestimations using Fermi modeling may have become pronounced in some of our subjects due to saturation effects in our single bolus data. This may explain its lower sensitivity in detecting hypoperfusion in obstructive CAD (susceptible to false negatives), compared to DP modeling.

Per vessel versus per patient quantitative analysis

The significant differences between (no, minor or non)-obstructive and obstructive CAD (Table 4 and 5), the AUC (Table 4, Figs. 3 and 5) and the diagnostic performance (Table 6) of both models were considerably superior in per patient analysis, compared to per vessel analysis. DP modeling-derived MBF at stress in per patient analysis demonstrated the highest diagnostic performance in detecting impaired haemodynamics in obstructive CAD (Table 6) and compares favourably against previous findings [9, 11]. These outcomes indicate that it may have merit for the stratification of patients with at least one vessel with obstructive CAD.

The specificities and positive predictive values in per vessel based analysis were in agreement with those reported by a previous study [19], but in a lower range compared to other investigations [5, 10]. Quantitative CMR analysis identified hypoperfusion in vessels with (no, minor or non)-obstructive CAD, which increased the false positives in per vessel analysis. 72 % of the patients with (no, minor or non)-obstructive disease had at least one vessel with obstructive CAD (Table 1). Also, the vast majority of the study participants had been referred for angina (96 %), were under treatment for cardiac arrhythmias and hypertension (beta blockers, 83 %), were under medication for hyperlipidemia (statins, 88 %) and were previous smokers (63 %), all high risk factors for microvascular dysfunction [29]. It is important to consider that microvascular dysfunction may have a major impact on global MBF [6, 29], which may also have affected myocardial perfusion in vessels with (no, minor or non)-obstructive CAD. The coincidental effect of microvascular dysfunction in these patients, could possibly explain the homogeneous deficiency in coronary blood flow detected with both quantitative modeling approaches.

Study limitations

The main limitation of this study is the small population size. However, this is a pilot study to assess the feasibility of applying the DP model in this cohort of patients with known or suspected CAD. The above methods need to be assessed in larger patient cohorts to further assess their diagnostic accuracy. For perfusion CMR, a single bolus protocol was implemented to eliminate patient discomfort, similar to previous quantitative perfusion CMR studies at 1.5T [11, 19, 20] and at 3T [10]. Thus, it was impossible to assess any MBF overestimations at the specific contrast agent dose (0.05 mmol/kg) used in this study, due to arterial input function saturation issues at 3T. Our group has previously shown that the DP model was less dependent on saturation effects, although at a lower contrast agent dose (0.03 mmol/kg) [12]. However, it is currently shown here that DP modeling achieved higher sensitivity and specificity in detecting obstructive CAD in our pilot cohort. This suggests that further investigation is required to determine whether DP modeling may be a more robust method of analysis for single bolus data at 3T, compared to the Fermi model. Any possible misregistration between the actual architecture of vessel territories and the standard 16-segment model used for myocardial segmentation [14] is a methodological consideration that should not be excluded in both visual and quantitative CMR analysis. Both types of analysis can be subject to overlap of vessel territories which could in turn affect their sensitivity and/or specificity [21]. Despite this, the reference method for quantitative CMR analysis of myocardial perfusion still occurs across the three major epicardial arteries [14] and this standard type of analysis was also implemented in this study.

Conclusions

Our analysis demonstrated that diagnostically, the DP model outperformed the standard Fermi model, in the setting of detecting hypoperfusion corresponding to haemodynamically significant stenotic vessel territories.

In per patient analysis, the diagnostic performance of DP modeling-derived MBF at stress outperformed both Fermi modeling and visual CMR analysis, whilst reaching the highest sensitivity and specificity for obstructive CAD detection in our pilot population. In the clinical setting, the haemodynamic threshold for DP-derived MBF at hyperaemia may have potential to be established as important biomarker, in order to stratify patients with at least one vessel with obstructive CAD.

Abbreviations

CAD, coronary artery disease; CMR, cardiovascular magnetic resonance; DP, distributed parameter model; MBF, myocardial blood flow; MOLLI, modified Look Locker inversion recovery; MPR, myocardial perfusion reserve; MPR2, myocardial perfusion reserve of the two lowest scoring segments; PET, positron emission tomography; ROC, receiver operating characteristic

References

  1. Jaarsma C, Leiner T, Bekkers SC, Crijns HJ, Wildberger JE, Nagel E, Nelemans PJ, Schalla S. Diagnostic Performance of Noninvasive Myocardial Perfusion Imaging Using Single-Photon Emission Computed Tomography, Cardiac Magnetic Resonance, and Positron Emission Tomography Imaging for the Detection of Obstructive Coronary Artery Disease. J Am Coll Cardiol. 2012;59:1719–28.

    Article  PubMed  Google Scholar 

  2. Nandalur KR, Dwamena BA, Choudhri AF, Nandalur MR, Carlos RC. Diagnostic performance of stress cardiac magnetic resonance imaging in the detection of coronary artery disease: a meta-analysis. J Am Coll Cardiol. 2007;50:1343–53.

    Article  PubMed  Google Scholar 

  3. Rieber J, Huber A, Erhard I, Mueller S, Schweyer M, Koenig A, Schiele TM, Theisen K, Siebert U, Schoenberg SO, Reiser M, Klauss V. Cardiac magnetic resonance perfusion imaging for the functional assessment of coronary artery disease: a comparison with coronary angiography and fractional flow reserve. Eur Heart J. 2006;27:1465–71.

    Article  PubMed  Google Scholar 

  4. Al-Saadi N, Nagel E, Gross M, Schnackenburg B, Paetsch I, Klein C, Fleck E. Improvement of myocardial perfusion reserve early after coronary intervention: assessment with cardiac magnetic resonance imaging. J Am Coll Cardiol. 2000;36:1557–64.

    Article  CAS  PubMed  Google Scholar 

  5. Morton G, Chiribiri A, Ishida M, Hussain ST, Schuster A, Indermuehle A, Perera D, Knuuti J, Baker S, Hedstrom E, Schleyer P, O’Doherty M, Barrington S, Nagel E. Quantification of absolute myocardial perfusion in patients with coronary artery disease: comparison between cardiovascular magnetic resonance and positron emission tomography. J Am Coll Cardiol. 2012;60(16):1546–55.

    Article  PubMed  Google Scholar 

  6. Kaufmann PA, Camici PG. Myocardial blood flow measurement by PET: technical aspects and clinical applications. J Nucl Med. 2005;46:75–88.

    PubMed  Google Scholar 

  7. Jerosch-Herold M, Wilke N, Stillman AE. Magnetic resonance quantification of the myocardial perfusion reserve with a Fermi function model for constrained deconvolution. Med Phys. 1998;25:73–84.

    Article  CAS  PubMed  Google Scholar 

  8. Sourbron SP, Buckley DL. Tracer kinetic modeling in MRI: estimating perfusion and capillary permeability. Phys Med Biol. 2012;57:R1–R33.

    Article  CAS  PubMed  Google Scholar 

  9. Patel AR, Antkowiak PF, Nandalur KR, West AM, Salerno M, Arora V, Christopher J, Epstein FH, Kramer CM. Assessment of advanced coronary arterydisease: advantages of quantitative cardiac magnetic resonance perfusion analysis. J Am Coll Cardiol. 2010;56(7):561–9.

    Article  PubMed  PubMed Central  Google Scholar 

  10. Lockie T, Ishida M, Perera D, Chiribiri A, De Silva K, Kozerke S, Marber M, Nagel E, Rezavi R, Redwood S, Plein S. High-resolution magnetic resonance myocardial perfusion imaging at 3.0-Tesla to detect hemodynamically significant coronary stenoses as determined by fractional flow reserve. J Am Coll Cardiol. 2011;57:70–5.

    Article  PubMed  Google Scholar 

  11. Biglands JD, Magee DR, Sourbron SP, Plein S, Greenwood JP, Radjenovic A. Comparison of the diagnostic performance of four quantitative myocardial perfusion estimation methods used in cardiac MR imaging. Radiol. 2015;275:393–402.

    Article  Google Scholar 

  12. Papanastasiou G, Williams MC, Kershaw LE, Dweck MR, Alam S, Mirsadraee S, Connell M, Gray C, MacGillivray T, Newby DE, Semple SIK. Measurement of myocardial blood flow by magnetic resonance perfusion imaging: comparison of distributed parameter and Fermi models with single and dual bolus. J Cardiov Magn Reson. 2015;17:17.

    Article  Google Scholar 

  13. Messroghli DR, Greiser A, Fröhlich M, Dietz R, Schulz-Menger J. Optimization and validation of a fully-integrated pulse sequence for modified look-locker inversion-recovery (MOLLI) T1 mapping of the heart. J Magn Reson Im. 2007;26:1081–6.

    Article  Google Scholar 

  14. Cerqueira MD, Weissman NJ, Dilsizian V, Jacobs AK, Kaul S, Laskey WK, Pennell DJ, Rumberger JA, Ryan T, Verani MS. Standardized Myocardial Segmentation and Nomenclature for Tomographic Imaging of the Heart: A Statement for Healthcare Professionals From the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation. 2002;105:539–42.

    Article  PubMed  Google Scholar 

  15. Tonino PAL, De Bruyne B, Pijls NHJ, Siebert U, Ikeno F, van’t Veer M, Klauss V, Manoharan G, Engstrom T, Oldroyd KG, Ver Lee PN, MacCarthy PA, Fearon WF. Fractional flow reserve versus angiography for guiding Percutaneous Coronary Intervention. N Engl J Med. 2009;360:213–24.

    Article  CAS  PubMed  Google Scholar 

  16. Tonino PAL, Fearon WF, De Bruyne B, Oldroyd KG, Leesar MA, Ver Lee PN, MacCarthy PA, van‟t Veer M, Pijls NHJ. Angiographic versus functional severity of coronary artery stenoses in the FAME study. J Am Coll Cardiol. 2010;55:2816–21.

    Article  PubMed  Google Scholar 

  17. Larsson HBW, Fritz-Hansen T, Rostrup E, Søndergaard L, Ring P, Henriksen O. Myocardial perfusion modeling using MRI. Magn Reson Med. 1996;35:716–26.

    Article  CAS  PubMed  Google Scholar 

  18. DeLong ER, DeLong DM, Clarke-Pearson DL. Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics. 1988;44(3):837–45.

    Article  CAS  PubMed  Google Scholar 

  19. Costa MA, Shoemaker S, Futamatsu H, Klassen C, Angiolillo DJ, Nguyen M, Siuciak A, Gilmore P, Zenni MM, Guzman L, Bass TA, Wilke N. Quantitative magnetic resonance perfusion imaging detects anatomic and physiologic coronary artery disease as measured by coronary angiography and fractional flow reserve. J Am Coll Cardiol. 2007;50(6):514–22.

    Article  PubMed  Google Scholar 

  20. Huber A, Sourbron S, Klauss V, Schaefer J, Bauner KU, Schweyer M, Reiser M, Rummeny E, Rieber J. Magnetic resonance perfusion of the myocardium: Semiquantitative and quantitative evaluation in comparison with coronary angiography and fractional flow reserve. Invest Radiol. 2012;47:332–8.

    Article  PubMed  Google Scholar 

  21. Hajjiri MM, Leavitt MB, Zheng H, Spooner AE, Fischman AJ, Gewirtz H. Comparison of positron emission tomography measurement of adenosine-stimulated absolute myocardial blood flow versus relative myocardial tracer content for physiological assessment of coronary artery stenosis severity and location. J Am Coll Cardiol Img. 2009;2:751–8.

    Article  Google Scholar 

  22. Danad I, Uusitalo V, Kero T, Saraste A, Raijmakers PG, Lammertsma AA, Heymans MW, Kajander SA, Pietila M, James S, Sorensen J, Knaapen P, Knuuti J. Quantitative Assessment of Myocardial Perfusion in the Detection of Significant Coronary Artery Disease: Cutoff Values and Diagnostic Accuracy of Quantitative [15O]H2O PET Imaging. J Am Coll Cardiol. 2014;64(14):1464–75.

    Article  PubMed  Google Scholar 

  23. Danad I, Raijmakers PG, Appelman YE, Harms HJ, de Haan S, van den Oever MLP, van Kuijk C, Allaart CP, Hoekstra OS, Lammertsma AA, Lubberink M, van Rossum AC, Knaapen P. Coronary risk factors and myocardial blood flow in patients evaluated for coronary artery disease: a quantitative [15O]H2O PET/CT study. Eur J Nucl Med Mol Imaging. 2012;39:102–12.

    Article  PubMed  Google Scholar 

  24. Kajander S, Joutsiniemi E, Saraste M, Pietila M, Ukkonen H, Saraste A, Sipila HT, Teras M, Maki M, Airaksinen J, Hartiala J, Knuuti J. Cardiac positron emission tomography/computed tomography imaging accurately detects anatomically and functionally significant coronary artery disease. Circulation. 2010;22:603–13.

    Article  Google Scholar 

  25. Karamitsos TD, Leccisotti L, Arnold JR, Recio-Mayoral A, Bhamra-Ariza P, Ruairidh K, Howells RK, Searle N, Robson MD, Rimoldi OE, Camici PG, Neubauer S, Selvanayagam JB. Relationship between regional myocardial oxygenation and perfusion in patients with coronary artery disease: insights from cardiovascular magnetic resonance and positron emission tomography. Circ Cardiovasc Imaging. 2010;3:32–40.

    Article  PubMed  Google Scholar 

  26. Broadbent DA, Biglands JD, Larghat A, Sourbron SP, Radjenovic A, Greenwood JP, Plein S, Buckley DL. Myocardial blood flow at rest and stress measured with dynamic contrast-enhanced MRI: Comparison of a distributed parameter model with a fermi function model. Magn Reson Med. 2013;70:1591–7.

    Article  CAS  PubMed  Google Scholar 

  27. Pack NA, DiBella EVR. Comparison of myocardial perfusion estimates from dynamic contrast-enhanced magnetic resonance imaging with four quantitative analysis methods. Magn Reson Med. 2010;64:125–37.

    Article  PubMed  PubMed Central  Google Scholar 

  28. Utz W, Greiser A, Niendorf T, Diet R, Schulz-Menger J. Single- or dual-bolus approach for the assessment of myocardial perfusion reserve in quantitative MR perfusion imaging. Magn Reson Med. 2008;59:1373–7.

    Article  PubMed  Google Scholar 

  29. Camici PG, Crea F. Coronary microvascular dysfunction. N Engl J Med. 2007;356(8):830–40.

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgements

We are grateful to Siemens Gmbh for supplying the Works in Progress software.

Funding

This work was made possible through funding and continued support from the British Heart Foundation (GP by the RE/08/001/23904, MCW, MRD and DEN by the FS/11/014, CH/09/002). DEN is the recipient of a Wellcome Trust Senior Investigator Award (WT103782AIA). The Centre for Cardiovascular Science is the recipient of a British Heart Foundation Centre of Research Excellence Award (RE/08/001). The Clinical Research Imaging Centre and Wellcome Trust Clinical Research Facility (Edinburgh) are supported by National Health Service Research Scotland (NRS).

Authors’ contributions

GP: Author of the manuscript. Conceptualized the objectives and developed the hypotheses of the manuscript. Participated in the design of the image acquisition protocol, prepared the data analysis software and performed quantitative and statistical analysis. MW: Recruited all patients, prepared subjects before the magnetic resonance (MR) imaging, supervised the scans and performed visual MR analysis. MD: Supervised the scans and performed visual MR analysis. SA: Prepared the subjects before the MR scanning and supervised the scans. AC: Participated in the development of the image acquisition protocol. SM: Performed qualitative assessment of the MR images and reported incidental findings. DN: Revised the manuscript. Gave final approval to be published and approved the validity of the research questions and scientific approaches. Planned the study, obtained funding. SS: Revised the manuscript. Gave final approval to be published and approved the validity of the research questions, methodology and scientific approaches. Planned the study, obtained funding. All authors read and approved the manuscript.

Competing interests

The authors declare that they have no competing interests.

Ethics approval and consent to participate

The study has been approved by the United Kingdom Research Ethics Committee. Informed consent was received from all subjects.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Giorgos Papanastasiou.

Additional files

Additional file 1:

Signal intensity and contrast agent concentration. The conversion process of signal intensity into contrast agent concentration curves is provided, using the MR pulse sequence equation. (DOCX 24 kb)

Additional file 2:

Fermi and distributed parameter modeling. Functions, fitted parameters and details are presented for both models. (DOCX 21 kb)

Additional file 3:

Microvascular characteristics. Functions of additional microvascular characteristics calculated with distributed parameter modeling. (DOCX 22 kb)

Additional file 4:

Microvascular characteristics values. Values of microvascular characteristics in per vessel and per patient analysis are provided. (DOCX 16 kb)

Additional file 5:

Bland Altman plots. Systematic bias was investigated between Fermi and distributed parameter modeling. (DOCX 268 kb)

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Papanastasiou, G., Williams, M.C., Dweck, M.R. et al. Quantitative assessment of myocardial blood flow in coronary artery disease by cardiovascular magnetic resonance: comparison of Fermi and distributed parameter modeling against invasive methods. J Cardiovasc Magn Reson 18, 57 (2016). https://doi.org/10.1186/s12968-016-0270-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12968-016-0270-1

Keywords