Study | Scanner manufacturer | Sequence | Magnetic field strength (T) | Coil channels | Fat suppression | Pre-pulse | Vasodilatory premedication | Contrast agent | Beta-blocker | Scan time (min) |
---|---|---|---|---|---|---|---|---|---|---|
Jahnke_2005 | Philips | SSFP | 1.5 | 5 | Yes | T2 preparation | No | No | No | 12 ± 2 |
Sakuma_2005 | Philips | SSFP | 1.5 | 5 | Yes | T2 preparation | Yes | No | No | 13.8 ± 3.8 |
Dewey_2006 | Siemens Medical Solutions | SSFP | 1.5 | 12 | Yes | None | Yes | No | No | N/A |
Kim_2006 | Philips Medical Systems | SSFP | 1.5 | Synergy cardiac coil | Yes (SPIR) | T2 preparation | N/A | N/A | N/A | 9.3 ± 2.1 |
Sakuma_2006 | Philips | SSFP | 1.5 | 5 | Yes | T2 preparation | Yes | No | No | 12.9 ± 4.3 |
Liu_2007 | GE Healthcare | SSFP | 1.5 | 6 | Yes | T2 preparation | Yes | No | Yes | N/A |
Maintz_2007 | Philips | SSFP | 1.5 | 5 | Yes (SPIR) | T2 preparation | No | No | Yes | 14 |
McCarthy_2007 | Siemens Medical Solutions | SSFP | 1.5 | 12 | Yes | N/A | No | No | No | 45 |
Klein_2008 | Philips | SSFP | 1.5 | 5 | Yes | T2 preparation | No | No | No | 6.3 ± 1.6 |
Oncel_2008 | Siemens | SSFP | 1.5 | N/A | Yes | T2 preparation | No | No | Yes | 13 |
Pouleur_2008 | Philips | SSFP | 1.5 | 5 | Yes | T2 preparation | No | No | No | 20 ± 4 |
Kunimasa_2009 | Philips | SSFP | 1.5 | 5 | N/A | T2 preparation | Yes | No | No | 9 ± 3.1 |
Langer_2009 | Philips | SSFP | 1.5 | 5 | Yes (SPIR) | T2 preparation | No | No | No | N/A |
Yang_2009 | Siemens | GRE | 3 | 12 | Yes | Inversion recovery | Yes | Yes | Yes | 9 ± 1.9 |
Chen_2010 | Siemens | GRE | 3 | 12 | Yes | Inversion recovery | Yes | Yes | No | 9.6 ± 3.2 |
Kato_2010 | Philips | SSFP | 1.5 | 5 | Yes | T2 preparation | No | No | No | 9.5 ± 3.5 |
Hamdan_2011 | Philips | GRE | 3 | 32 | Yes | T2 preparation | Yes | No | Yes | 17 ± 4.7 |
Nagata_2011 | Philips | SSFP | 1.5 | 32 | Yes | T2 preparation | Yes | No | No | 6.2 ± 2.8 |
Wagner_2011 | Siemens | SSFP | 1.5 | 32 | Yes | T2 preparation | Yes | Yes | No | 9.1 ± 2 |
Yang_2012 | Siemens | GRE | 3 | 32 | N/A | Inversion recovery | Yes | Yes | Yes | 7 ± 1.8 |
Bettencourt_2013 | Siemens | SSFP | 1.5 | 12 | Yes | T2 preparation | Yes | Yes | Yes | 17.9 ± 4.6 |
Cheng_2013 | General Electric Healthcare Technologies | SSFP | 1.5 | 8 | Yes | T2 preparation | Yes | No | Yes | N/A |
Heer_2013 | GE | SSFP | 1.5 | 8 | Yes | T2 preparation | Yes | No | Yes | 14.3 ± 6.2 |
Piccini_2014 | Siemens | SSFP | 1.5 | 30 | Yes | T2 preparation | N/A | Yes | No | 7.8 ± 1.9 |
Yonezawa_2014 | Philips | SSFP | 1.5 | 32 | Yes | T2 preparation | Yes | No | No | 6.8 ± 2.6 |
Yun_2014 | Siemens | GRE | 3 | 12 | Yes (SPIR) | Inversion recovery | No | Yes | No | 10.3 ± 2.5 |
He_2016 | Siemens | GRE | 3 | 32 | Yes | Inversion recovery | No | Yes | No | 7.8 ± 0.8 |
Namba_2016 | Philips | SSFP | 3 | 32 | Yes (SPIR) | T2 preparation | Yes | Yes | No | 278 ± 43 s |
Chen_2018 | Siemens | GRE | 3 | 12 | Yes | Inversion recovery | Yes | Yes | Yes | 9.5 ± 3.1 |
Zhang_2018 | Siemens | GRE | 3 | 32 | Yes | Inversion recovery | N/A | Yes | No | 10.4 ± 3.2 |
Sun_2020 | Siemens | GRE | 3 | 12 | Yes | Inversion recovery |  | Yes | Yes | 9.5 ± 3.1 |
Lin_2021 | Philips | SSFP | 1.5 | 32 | Yes (SPIR) | T2 preparation | No | No | No | 10.2 ± 2.4 |
Lu_2022 | Philips | GRE | 3 | 32 | N/A | T2 preparation | No | No | No | 7.88 ± 2.78 |
Nazir_2022 | Siemens | SSFP | 1.5 | 32 | Yes (SPIR) | T2 preparation | Yes | No | Yes | 10.4 ± 2.1 |