Table 2 Information of magnetic resonance imaging

From: Diagnostic accuracy of whole heart coronary magnetic resonance angiography: a systematic review and meta-analysis

Study

Scanner manufacturer

Sequence

Magnetic field strength (T)

Coil channels

Fat suppression

Pre-pulse

Vasodilatory premedication

Contrast agent

Beta-blocker

Scan time (min)

Jahnke_2005

Philips

SSFP

1.5

5

Yes

T2 preparation

No

No

No

12 ± 2

Sakuma_2005

Philips

SSFP

1.5

5

Yes

T2 preparation

Yes

No

No

13.8 ± 3.8

Dewey_2006

Siemens Medical Solutions

SSFP

1.5

12

Yes

None

Yes

No

No

N/A

Kim_2006

Philips Medical Systems

SSFP

1.5

Synergy cardiac coil

Yes (SPIR)

T2 preparation

N/A

N/A

N/A

9.3 ± 2.1

Sakuma_2006

Philips

SSFP

1.5

5

Yes

T2 preparation

Yes

No

No

12.9 ± 4.3

Liu_2007

GE Healthcare

SSFP

1.5

6

Yes

T2 preparation

Yes

No

Yes

N/A

Maintz_2007

Philips

SSFP

1.5

5

Yes (SPIR)

T2 preparation

No

No

Yes

14

McCarthy_2007

Siemens Medical Solutions

SSFP

1.5

12

Yes

N/A

No

No

No

45

Klein_2008

Philips

SSFP

1.5

5

Yes

T2 preparation

No

No

No

6.3 ± 1.6

Oncel_2008

Siemens

SSFP

1.5

N/A

Yes

T2 preparation

No

No

Yes

13

Pouleur_2008

Philips

SSFP

1.5

5

Yes

T2 preparation

No

No

No

20 ± 4

Kunimasa_2009

Philips

SSFP

1.5

5

N/A

T2 preparation

Yes

No

No

9 ± 3.1

Langer_2009

Philips

SSFP

1.5

5

Yes (SPIR)

T2 preparation

No

No

No

N/A

Yang_2009

Siemens

GRE

3

12

Yes

Inversion recovery

Yes

Yes

Yes

9 ± 1.9

Chen_2010

Siemens

GRE

3

12

Yes

Inversion recovery

Yes

Yes

No

9.6 ± 3.2

Kato_2010

Philips

SSFP

1.5

5

Yes

T2 preparation

No

No

No

9.5 ± 3.5

Hamdan_2011

Philips

GRE

3

32

Yes

T2 preparation

Yes

No

Yes

17 ± 4.7

Nagata_2011

Philips

SSFP

1.5

32

Yes

T2 preparation

Yes

No

No

6.2 ± 2.8

Wagner_2011

Siemens

SSFP

1.5

32

Yes

T2 preparation

Yes

Yes

No

9.1 ± 2

Yang_2012

Siemens

GRE

3

32

N/A

Inversion recovery

Yes

Yes

Yes

7 ± 1.8

Bettencourt_2013

Siemens

SSFP

1.5

12

Yes

T2 preparation

Yes

Yes

Yes

17.9 ± 4.6

Cheng_2013

General Electric Healthcare Technologies

SSFP

1.5

8

Yes

T2 preparation

Yes

No

Yes

N/A

Heer_2013

GE

SSFP

1.5

8

Yes

T2 preparation

Yes

No

Yes

14.3 ± 6.2

Piccini_2014

Siemens

SSFP

1.5

30

Yes

T2 preparation

N/A

Yes

No

7.8 ± 1.9

Yonezawa_2014

Philips

SSFP

1.5

32

Yes

T2 preparation

Yes

No

No

6.8 ± 2.6

Yun_2014

Siemens

GRE

3

12

Yes (SPIR)

Inversion recovery

No

Yes

No

10.3 ± 2.5

He_2016

Siemens

GRE

3

32

Yes

Inversion recovery

No

Yes

No

7.8 ± 0.8

Namba_2016

Philips

SSFP

3

32

Yes (SPIR)

T2 preparation

Yes

Yes

No

278 ± 43 s

Chen_2018

Siemens

GRE

3

12

Yes

Inversion recovery

Yes

Yes

Yes

9.5 ± 3.1

Zhang_2018

Siemens

GRE

3

32

Yes

Inversion recovery

N/A

Yes

No

10.4 ± 3.2

Sun_2020

Siemens

GRE

3

12

Yes

Inversion recovery

 

Yes

Yes

9.5 ± 3.1

Lin_2021

Philips

SSFP

1.5

32

Yes (SPIR)

T2 preparation

No

No

No

10.2 ± 2.4

Lu_2022

Philips

GRE

3

32

N/A

T2 preparation

No

No

No

7.88 ± 2.78

Nazir_2022

Siemens

SSFP

1.5

32

Yes (SPIR)

T2 preparation

Yes

No

Yes

10.4 ± 2.1

  1. BMI body mass index, CAD coronary artery disease, GRE gradient echo, SSFP steady state free precession, SPIR spectral presaturation with inversion recovery, N/A not applicable