Table 7 A comparative analysis of sensitivity, specificity, and AUC between Asian and Western countries

From: Diagnostic accuracy of whole heart coronary magnetic resonance angiography: a systematic review and meta-analysis

 

1.5 T WHCA (Asian countries) (N = 10 studies)

1.5 T WHCA (Western countries) (N = 13 studies)

P-value

Patient-based analysis

 Sensitivity

0.86 (0.80–0.90)

0.84 (0.75–0.90)

0.66

 Specificity

0.89 (0.78–0.95)

0.81 (0.62–0.78)

0.17

 AUC

0.9

0.84

N/A

Vessel-based analysis

 Sensitivity

0.84 (0.77–0.89)

0.81 (0.70–0.88)

0.58

 Specificity

0.84 (0.74–0.90)

0.79 (0.71–0.85)

0.35

 AUC

0.91

0.86

N/A

Segment-based analysis

 Sensitivity

0.85 (0.81–0.88)

0.76 (0.61–0.86)

0.17

 Specificity

0.93 (0.85–0.97)

0.91 (0.86–0.94)

0.59

 AUC

0.87

0.92

N/A

  1. Data are weighted mean ± 95% confidence interval
  2. AUC area under the curve, WHCA whole heart coronary magnetic resonance angiography