Skip to main content

Table 4 ROC-analysis and predicitve values for ECG-LVH criteria to detect CMR-LVH

From: Electrocardiographic diagnosis of left ventricular hypertrophy in aortic valve disease: evaluation of ECG criteria by cardiovascular magnetic resonance

 

ROC-AUC (95%-CI)

Sensitivity (%)

Specificity (%)

PPV (%)

NPV (%)

ACC (%)

Gubner-Ungerleider

0.72 (0.64 – 0.81)

34

90

88

39

52

Sokolow-Lyon product

0.86 (0.79 – 0.92)

51

96

90

46

65

Cornell voltage

0.78 (0.70 – 0.86)

52

87

91

48

63

Cornell product

0.81 (0.73 – 0.89)

56

87

96

48

66

Sokolow-Lyon voltage

0.80 (0.73 – 0.88)

57

90

92

49

67

Romhilt-Estes

0.87 (0.80 – 0.94)

n.a.

n.a.

n.a.

n.a.

n.a.

Romhilt-Estes 5p

n.a.

66

85

91

54

72

Romhilt-Estes 4p

n.a.

86

81

91

74

85

Perugia score

n.a.

80

77

88

65

79

  1. ROC, receiver-operating-characteristics; AUC, area under curve; CI, confidence interval; PPV, positive predictive value; NPV, negative predictive value; ACC, accuracy; n.a., not applicable