Skip to main content

Table 1 Mean EDV, ESV and EF values ± SD and ranges as determined by reader 1 and 2 with the SoS and GPM approach, respectively

From: Accuracy of single breath-hold cine MRI analyzed by guide-point modeling for the assessment of Left Ventricular Function

  Stack of short axis views + SoS Multi-orientation sequences + GPM
EF   
R1 53.3% ± 13.5% (range 15–73%) 52.8% ± 13.1% (range 15–71%)
R2 52.8% ± 12.5% (range 16–72%) 53.2% ± 12.6% (range 16–72%)
EDV   
R1 148.1 ml ± 57.2 ml (range 85–352 ml) 163.8 ml ± 64.5 ml (range 93–409 ml)
R2 147.4 ml ± 55.0 ml (range 79–331 ml) 165.5 ml ± 63.0 ml (range 98–392 ml)
ESV   
R1 75.4 ml ± 58.0 ml (range 23–299 ml) 84.8 ml ± 66.2 ml (range 28–335 ml)
R2 75.5 ml ± 54.3 ml (range 22–274 ml) 84.1 ml ± 63.0 ml (range 28–321 ml)
  1. R2 = reader 2, EDV = end-diastolic volume, ESV = end-systolic volume, EF = ejection fraction, SoS = summation of slices, GPM = guide-point modeling.