Skip to main content

Table 1 Bland Altman analysis and coefficients of variability for RV functional metrics between reviewers

From: Efficiency and reproducibility of the right ventricular long axis imaging plane for the evaluation of right ventricle

  Mean difference (reviewer 1 - reviewer 2) Upper limit of agreement Lower limit of agreement CoV
RVEDV (mL)     
RHLA 11.5 (5.5, 17.6) 46.4 (35.8, 56.9) -23.3 (-33.8, -12.8) 8.4
SAX 23.1 (14.1, 32.1) 74.6 (59.1, 90.2) -28.4 (-44.0, -12.9) 13.0
RVESV (mL)     
RHLA 8.1 (0.7, 15.4) 50.2 (37.4, 62.9) -34.1 (-46.8, -21.3) 19.5
SAX 16.7 (8.0, 25.4) 66.7 (51.6, 81.7) -33.3 (-48.3, -18.2) 22.5
RVEF (%)     
RHLA -1.4 (-3.0, 0.2) 7.7 (4.9, 10.4) -10.5 (-13.2, -7.7) 9.1
SAX -2.5 (-4.9, -0.2) 11.0 (6.9, 15.0) -16.0 (-20.0, - 11.9) 14.6
  1. Note - values in parenthesis are 95% CI.