Skip to main content

Table 1 Myocardial and blood pool T1 as well as myocardial ECV values using both the 17 HB and 11 HB MOLLI sequences at different time points (Average ± standard deviation)

From: Myocardial T1 and extracellular volume fraction mapping at 3 tesla

Structure

Sequence

Pre-Contrast

Post 3.5 min

Post 5 min

Post 8.5 min

Post 13.5 min

Post 18.5 min

Post 23.5 min

Myocardium T1 (ms)

17 HB MOLLI

1,324 ± 48

426 ± 44

476 ± 42

526 ± 31

583 ± 43

622 ± 40

661 ± 38

Myocardium T1 (ms)

11 HB MOLLI

1,314 ± 39

441 ± 50

467 ± 43

537 ± 52

583 ± 48

619 ± 48

659 ± 52

Blood pool T1 (ms)

17 HB MOLLI

2,037 ± 152

246 ± 33

282 ± 38

331 ± 37

384 ± 38

433 ± 42

462 ± 41

Blood pool T1(ms)

11 HB MOLLI

2,020 ± 128

255 ± 39

269 ± 22

337 ± 43

390 ± 44

429 ± 39

469 ± 42

Myocardium ECV (%)

17 HB MOLLI

N/A

25.5 ± 4.1

26.4 ± 3.8

26.5 ± 3.8

27.3 ± 4.2

26.1 ± 3.4

26.3 ± 3.8

Myocardium ECV (%)

11 HB MOLLI

N/A

24.2 ± 3.8

25.7 ± 3.8

26.5 ± 4.4

27.2 ± 4.6

26.7 ± 3.9

25.8 ± 4.1