Skip to main content

Advertisement

Table 1 Myocardial and blood pool T1 as well as myocardial ECV values using both the 17 HB and 11 HB MOLLI sequences at different time points (Average ± standard deviation)

From: Myocardial T1 and extracellular volume fraction mapping at 3 tesla

Structure Sequence Pre-Contrast Post 3.5 min Post 5 min Post 8.5 min Post 13.5 min Post 18.5 min Post 23.5 min
Myocardium T1 (ms) 17 HB MOLLI 1,324 ± 48 426 ± 44 476 ± 42 526 ± 31 583 ± 43 622 ± 40 661 ± 38
Myocardium T1 (ms) 11 HB MOLLI 1,314 ± 39 441 ± 50 467 ± 43 537 ± 52 583 ± 48 619 ± 48 659 ± 52
Blood pool T1 (ms) 17 HB MOLLI 2,037 ± 152 246 ± 33 282 ± 38 331 ± 37 384 ± 38 433 ± 42 462 ± 41
Blood pool T1(ms) 11 HB MOLLI 2,020 ± 128 255 ± 39 269 ± 22 337 ± 43 390 ± 44 429 ± 39 469 ± 42
Myocardium ECV (%) 17 HB MOLLI N/A 25.5 ± 4.1 26.4 ± 3.8 26.5 ± 3.8 27.3 ± 4.2 26.1 ± 3.4 26.3 ± 3.8
Myocardium ECV (%) 11 HB MOLLI N/A 24.2 ± 3.8 25.7 ± 3.8 26.5 ± 4.4 27.2 ± 4.6 26.7 ± 3.9 25.8 ± 4.1