Skip to main content

Table 1 Comparison between TTE and PC MRI using the three methods for AVA estimation (*p<0.05)

From: Evaluation of aortic valve stenosis from Phase-Contrast Magnetic Resonance data using a new automated segmentation and analysis method: Comparison against Doppler Echocardiography

 

Mean (SD) of differences compared to TTE (cm2)

Correlation Coefficient R

Intra-class coefficient between TTE and PC MR

Specificity to detect severe stenosis (%)

Sensibility to detect severe stenosis (%)

AVA1

-0,50 (0,57)*

0,92

0 ,67

94

97

AVA2

+0,02 (0,37)

0,94

0,94

100

97

AVA3

+0,07 (0,29)

0,97

0,96

100

97