Skip to main content

Table 3 Quantitative Cine CMR Results

From: Comparison of exercise electrocardiography and stress perfusion CMR for the detection of coronary artery disease in women

Parameter

Entire Group

(n=68)

CAD†

(n=20)

No CAD

(n=48)

P

LV Ejection Fraction (%)

65.9±10.1

63.8±10.1

66.8±10.0

0.28

LV-EDV (ml)

95.4±22.8

86.7±18.2

99.1±23.7

0.04

LV-ESV (ml)

33.4±15.8

32.0±13.6

34.0±16.7

0.64

LV-mass (g)

103.6±22.5

103.5±25.5

103.6±21.4

0.99

LV-EDV Index (ml/m 2 )

53.6±12.1

50.2±9.5

55.0±12.9

0.14

LV-ESV Index (ml/m 2 )

18.8±9.4

18.4±7.4

19.0±10.2

0.83

LV-mass Index (gm/m 2 )

58.3±12.4

60.0±14.4

57.5±11.6

0.45

  1. CMR = cardiovascular magnetic resonance, CAD = coronary artery disease, LV = left ventricle, EDV = end-diastolic volume, ESV = end-systolic volume.