Systolic versus diastolic myocardial blood flow in patients with suspected coronary artery disease - a cardiovascular magnetic resonance study
Journal of Cardiovascular Magnetic Resonance volume 14, Article number: P17 (2012)
Summary
This study has shown that in patients with suspected and confirmed CAD, estimates of MBF by perfusion-CMR are significantly higher in diastole than systole during maximal hyperemic stress.
Background
Differences in myocardial blood flow (MBF) between systole and diastole have been reported in healthy volunteers but the impact of cardiac phase on detecting coronary artery disease (CAD) is unknown [1]. This study aimed to compare MBF estimates from cardiovascular magnetic resonance (perfusion-CMR) imaging in systole and diastole in patients with suspected CAD and determine if either phase has greater diagnostic accuracy.
Methods
Following invasive coronary angiography, 40 patients (68% men, 64 ± 8 yrs) underwent stress perfusion-CMR (1.5T Philips) acquired at mid-systole and end-diastole simultaneously [1]. Based on angiographic stenosis >70%, patients were grouped as having ‘CAD’ or ‘no CAD’. In patients with CAD, myocardial segments were classified as ‘stenosis-dependent’ (downstream of a significant stenosis) or ‘remote’. For each segment, MBF (Fermi-constrained deconvolution) and myocardial perfusion reserve (MPR) were calculated. The diagnostic accuracy of each phase was determined with receiver operator characteristic analysis.
Results
Twenty-one patients (53%) had CAD. A typical example of a patient with ischemia is shown in Figure 1. Resting MBF was similar in the two cardiac phases for both normal and CAD patients (all p values > 0.05). MBF at stress was greater in diastole than systole in normal, remote and stenosis-dependent segments (3.75 ± 1.5 vs. 3.15 ± 1.1 ml/g/min; 2.75 ± 1.20 vs. 2.38 ± 0.99 ml/g/min; 2.49 ± 1.07 vs. 2.23 ± 0.90 ml/g/min; all p values < 0.01). MPR was also greater in diastole than systole in all three segment groups (all p values <0.05) (Figure 2). On receiver operator characteristic analysis, the optimal MPR cut-off for the detection of CAD was 1.95 for systole and 2.04 for diastole (area under curve 0.82 vs. 0.79; p=0.30).
Conclusions
Estimates of stress MBF and MPR by perfusion-CMR in this study were greater in diastole than systole in normal and CAD patients. Although the diagnostic accuracy of both phases was similar, the MPR cut-off values were different. These observations are particularly important in the emerging field of 3D perfusion-CMR where the acquisition phase may be specifically chosen. Different estimates of MBF and different MPR cut-off values between phases mean a universal standard needs to be agreed for 3D acquisitions.
Funding
S.P is funded by a British Heart Foundation fellowship (FS/10/62/28409).
S.P and J.P.G received an unrestricted educational research grant from Philips Healthcare.
References
Radjenovic A, Biglands JD, Larghat A, et al: Estimates of systolic and diastolic myocardial blood flow by dynamic contrast-enhanced MRI. Magn Reson Med. 2010, 64 (6): 1696-703. 10.1002/mrm.22538.
Author information
Authors and Affiliations
Rights and permissions
This article is published under license to BioMed Central Ltd. This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
About this article
Cite this article
Motwani, M., Fairbairn, T., Larghat, A.M. et al. Systolic versus diastolic myocardial blood flow in patients with suspected coronary artery disease - a cardiovascular magnetic resonance study. J Cardiovasc Magn Reson 14 (Suppl 1), P17 (2012). https://doi.org/10.1186/1532-429X-14-S1-P17
Published:
DOI: https://doi.org/10.1186/1532-429X-14-S1-P17