From: CMR endpoints for clinical trials: impact of operator experience on the accuracy of image analysis
Observer | Â | EDV* (ml) | ESV (ml) | Mass (g) | IS* (g) |
---|---|---|---|---|---|
1 vs 2 | Mean (SD) difference | 6.51 (8.92) | 0.04 (0.13) | 11.38 (15.08) | -0.15 (0.49) |
1 vs 2 | Mean (SD) | 150.59 (30.29) | 4.20 (0.40) | 128.48 (26.95) | 2.86 (1.06) |
1 vs 2 | Coefficient of variation (%) | 5.92 | 3.04 | 11.74 | 17.04 |
1 vs 3 | Mean (SD) difference | 29.70 (15.83) | 0.26 (0.23) | 43.47 (26.81) | -0.74 (0.58) |
1 vs 3 | Mean (SD) | 160.95 (36.28) | 4.31 (0.41) | 145.62 (35.55) | 2.65 (1.01) |
1 vs 3 | Coefficient of variation (%) | 9.84 | 5.29 | 18.41 | 21.75 |