Skip to main content

Table 2 Image acquisition: image acquisition parameters for the challenge LGE data

From: Evaluation of current algorithms for segmentation of scar tissue from late Gadolinium enhancement cardiovascular magnetic resonance of the left atrium: an open-access grand challenge

 

U. Utah

BIDMC

KCL-IM

Scanner type

Siemens Avanto 1.5T or Vario 3T

Philips Acheiva 1.5T

Philips Achieva 1.5 T

Basic params

Free-breathing (FB) with navigator-gating

FB and navigator-gating with fat suppression

FB with navigator-gating with fat suppression

TI † , TR, TE

300 ms, 5.4 ms, 2.3 ms

280 ms, 5.3 ms, 2.1 ms

280 ms, 5.3 ms, 2.1 ms

Acquired resolution

1.25 × 1.25 × 2.5mm

1.4 × 1.4 × 1.4mm

1.3 × 1.3 × 4.0mm

Pre-scan

< 7 days

< 7 days

< 48 hours

Post-scan

3 - 6 months

= 30 days

3 - 6 months

  1. †- set to null myocardium.
  2. Abbreviations: TI Inversion time, TR Repetition time, TE Echo time. Imaging centres: U. Utah University of Utah, BIDMC Beth Israel Deaconess Medical Center, KCL-IM Imaging Sciences, King’s College London.