Skip to main content

Table 2 Inter-study reproducibility of LV strain and strain rates

From: Inter-study reproducibility of cardiovascular magnetic resonance tagging

LV parameter

Slice

Exam 1

Exam 2

Mean difference (SD)

ICC

SEM

SDC

Ecc, %

Base

−14.2

−13.9

−0.2 (1.6)

0.74**

0.8

2.3

Mid

−14.7

−15.2

0.5 (1.9)

0.73**

1.0

2.7

Apex

−15.6

−15.01

−0.6 (1.2)

0.89**

0.4

1.1

Err, %

Base

18.4

19.1

−0.7(5.3)

0.2

4.7

13.1

Mid

16.6

17.1

0.5 (4.1)

0.58*

2.7

7.4

Apex

15.1

13.9

1.2 (6.8)

0.3

5.7

15.8

Lambda 1, %

Base

23.1

24.0

−1.1 (5.2)

0.4*

4.0

11.2

Mid

22.8

23.1

0.3 (5.2)

0.6**

3.3

9.1

Apex

21.2

23.2

2.04 (7.2)

0.47*

5.2

14.5

Lambda 2, %

Base

−16.1

−16.6

0.5 (1.9)

0.66**

1.1

3.1

Mid

−17.2

−17.6

0.4 (2.3)

0.5*

1.6

4.5

Apex

−18.7

−19.4

0.7 (2.8)

0.47*

2.0

5.6

Angle, α

Base

11.4

10.0

1.3 (4.8)

0.05

4.7

13.0

Mid

13.3

12.1

1.1 (5.6)

0.05

5.5

15.1

Apex

16.2

17.2

−0.9 (6.6)

0.06

6.4

17.7

Time to peak Ecc (ms)

Mid

295.8

306

−10.4 (81)

0.4 *

62.7

173.8

SSR (1/s)

Mid

−79.6

−85.1

5.4 (15.7)

0.58*

10.2

28.2

EDSR (1/s)

Mid

72.2

70.8

1.4 (43.7)

0.35*

35.2

97.6

  1. SSR systolic circumferential strain rate, EDSR Early diastolic circumferential strain rate.
  2. SD standard deviation of mean difference, ICC Intra-class correlation coefficient, SEM standard error of measurement, SDC Smallest detectable change.
  3. ** = p <0.0001, * = p <0.05.