Skip to main content

Table 3 Evaluations of real-time and cine SSFP CMR (19 patients)

From: Real-time cardiovascular magnetic resonance at 1.5 T using balanced SSFP and 40 ms resolution

 

Real-time CMR free breathing

Beat-to-beat variation

Cine CMR breath-holding

Myocardial mass/g

35.5 ± 10.5

± 4%

35.1 ± 10.5

Enddiastolic left-ventricular volume/ml

49.5 ± 13.9

± 3%

52.1 ± 18.2

Endsystolic left-ventricular volume/ml

26.7 ± 13.9

± 4%

24.4 ± 11.9

Stroke volume/ml

22.8 ± 5.2

± 7%

28.5 ± 15.7

Ejection fraction/%

49 ± 12#

± 5%

55 ± 14

  1. Values (mean ± standard deviation) were obtained from three short-axis views and averaged across patients (cine CMR covering 10–12 heartbeats) and cardiac cycles (real-time CMR, 5 consecutive heartbeats, beat-to-beat variation).
  2. #Statistically significant different from cine CMR (paired t test).