Table 1 Quantitative CMR measurements and p-values from the two-sample t-test comparing patients who underwent pericardial stripping to those who did not.

From: Predictive value of cardiac magnetic resonance for the diagnosis and surgical relief of pericardial constriction

 

Pericardium stripped (n = 18)

Not stripped (n = 18)

 
 

Mean

SD

Min

Max

Mean

SD

Min

Max

p-value

IVC area (cm2)

9.59

2.59

6.3

14.6

5.02

1.36

3.0

7.5

<0.001*

Indexed IVC area (cm2/m2)

4.93

1.47

3.1

7.9

2.77

0.74

1.4

4.0

<0.001*

I:A ratio

2.56

0.76

1.4

4.0

1.28

0.27

0.7

1.8

<0.001*

Maximum pericardial thickness (mm)

5.50

2.77

2

12

1.72

0.57

1

3

<0.001*

RA AP diameter (cm)

5.17

1.15

3.2

7.9

5.00

1.21

3.1

6.9

0.664

RA TV diameter (cm)

4.81

0.91

3.4

6.4

4.99

1.18

2.7

8.4

0.605

RA area (cm2)

20.49

8.52

7.3

40.7

22.24

8.62

9.0

43.1

0.546

Indexed RA area (cm2/m2)

10.31

3.83

4.8

19.0

12.02

4.22

6.0

22.8

0.209

RV area (cm2)

15.86

6.31

9.3

29.7

22.11

6.38

13.6

34.0

0.006*

Indexed RV area (cm2/m2)

7.95

2.77

4.8

14.4

12.13

3.35

7.3

18.5

<0.001*