Skip to main content

Table 5 Comparison of previously published ADC and FA values with those measured in this study

From: Intercentre reproducibility of cardiac apparent diffusion coefficient and fractional anisotropy in healthy volunteers

Reference

Field strength (T)

Voxel size (mm3)

ADC (x10-3 mm2/s)

FA

Notes

Healthy volunteers

Disease

Healthy volunteers

Disease

(% change)

(% change)

Reese et al. [8]

1.5

3 × 3 × 9

0.87 ± 0.11

 

0.65 ± 0.03

  

Dou et al. [10]

1.5

4 × 4 × 12

0.60 ± 0.11

 

0.7 ± 0.1

  

Tseng et al. [1] (HCM)

1.5

3 × 3 × 3

not reported

 

0.78

0.75 (-4%)

Free wall

0.72

0.56 (-22%)

Septum

Wu et al. [2] (MI)

1.5

1.9 × 1.9 × 8

0.65 ± 0.03

0.92 (+46%)

0.33 ± 0.02

0.25 (-26%)

Acute

0.74 (+17%)

0.27 (-21%)

Chronic

Nielles-Vallespin et al. [12]

3.0

2.9 × 2.9 × 8

0.8 ± 0.1

-

0.60 ± 0.04

-

 

McGill et al. [22] (HCM)

3.0

2.9 × 2.9 × 8

-

0.73 (-9%)

-

0.62 (+3%)

This work

3.0

2.9 × 2.9 × 8

1.10 ± 0.06

 

0.41 ± 0.04

 

Systole

1.20 ± 0.09

0.54 ± 0.03

Diastole

  1. Caption: This table includes mean healthy values for systolic ADC and FA (±standard deviation where stated) using monopolar STEAM DT-CMR sequences previously reported in the literature, and changes reported in two diseases: hypertrophic cardiomyopathy (HCM) and acute and chronic myocardial infarction (MI).