Table 1 LV functional parameters for the FULL acquisition, and difference from this for each accelerated sequence.

From: Accuracy of compressed sensing for left ventricular mass and volumes

 

EDV

mean ± std (mL)

ESV

mean ± std (mL)

EF

mean ± std (%)

Mass

mean ± std (g)

FULL

146.0 ± 31.6

56.9 ± 16.3

61.4 ± 4.0

113.9 ± 30.3

FULL minus R4

-1.2 ± 5.5

-2.4 ± 3.4 *

1.4 ± 1.9

-7.2 ± 7.1*

FULL minus R9.2

7.3 ± 5.8**

-2.7 ± 4.8

4.1 ± 2.6**

-4.7 ± 6.2**

  1. p values represent repeated measures Bonferroni corrected ANOVA, * represents 0.05 < p < 0.01,** represents p < 0.01