Skip to main content

Volume 18 Supplement 1

19th Annual SCMR Scientific Sessions

  • Oral presentation
  • Open access
  • Published:

Combined ventricular output and oxygen delivery are reduced while oxygen extraction fraction is increased in fetuses with Ebstein's Anomaly by MRI

Background

Ebstein's anomaly (EA) has variable prognosis. New MRI technology allowing the measurement of vessel blood flow and oxygen content could provide additional prognostic information in the setting of fetal EA.

Methods

We measured fetal weight, brain weight and lung volume in normal and EA fetuses using MRI. Blood flow and T2 in the major fetal vessels were measured using our previously published technique. Fetal oxygen delivery (DO2), consumption (VO2) and extraction fraction (OEF) were calculated using estimated fetal hemoglobin concentration.

Results

We studied 30 normal and 8 EA fetuses at 36 weeks gestation. There were 2 deaths in the 4 patients that underwent surgery (all Starnes procedures). We found reduced flows in all measured vessels except ascending aorta (Table 1). There were also significant reduced T2s in ascending aorta and superior vena cava, but no difference in umbilical vein (UV) and descending aorta (Table 1). DO2 was lower, but increases in OEF maintained normal VO2 in EA fetuses (Table 2). Fetal weight and brain weight were lower in EA fetuses, while lung volume was not significantly different (Table 2). Within the EA group, UV flow (P = 0.04), VO2 (P < 0.0001) and lung volume (P = 0.03) were significantly higher in EA newborns not requiring surgery than EA newborn that received surgery.

Table 1 MRI measured flow and T2 in major fetal vessels in normal and Ebstein's anomaly fetuses.
Table 2 Oxygen consumption, oxygen delivery and oxygen extraction fraction, fetal weight Z score, fetal brain weight Z score and lung volume in normal and Ebstein's anomaly fetuses.

Conclusions

MRI revealed a ~50% reduction in CVO in EA fetuses compared to normal fetuses, which is greater than any other type of CHD. While EA subjects had similar placental function (indicated by similar UV T2), lower CVO resulted in reduced UV flow, therefore decreased DO2. EA fetuses had increased OEF compensating for the reduced DO2, but body and brain development were still reduced. In addition, MRI-based lung volume measurements, UV flow and VO2 maybe associated with postnatal outcome in EA fetuses. Therefore, with more experience, the MRI technique may provide useful prognostic information in Ebstein's anomaly pregnancies.

Author information

Authors and Affiliations

Authors

Rights and permissions

This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Zhu, M.Y., Stochitoiu, I.A., Jaeggi, E. et al. Combined ventricular output and oxygen delivery are reduced while oxygen extraction fraction is increased in fetuses with Ebstein's Anomaly by MRI. J Cardiovasc Magn Reson 18 (Suppl 1), O71 (2016). https://doi.org/10.1186/1532-429X-18-S1-O71

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/1532-429X-18-S1-O71

Keywords