Table 1 Comparison of the main diagnostic and quality assessment parameters for 2D and iNav3D LGE.

From: Clinical Evaluation of 3D High Resolution Late Enhancement using Image-Based Navigation

DIAGNOSTIC PERFORMANCE
Global LGE detection (p, 0.13)
2D (n = 22) 77% (17)
iNav3D (n = 22) 59% (13)
Segmental LGE detection (p, 0.28)
Number of segments 0 1 2 3 4 5
2D (n = 352) 75.9% (267) 10.2% (36) 3.7% (13) 7.7% (27) 2% (7) 0.6% (2)
iNav 3D (n = 352) 78.1% (275) 8.5% (30) 2% (7) 7.4% (26) 3.4% (12) 0.6% (2)
IMAGE QUALITY
Mean (SD) 2D LGE iNav 3D LGE p value
Quality (n = 22) 3 (0.9) 3.4 (0.8) 0.34
LGE- blood pool sharpness (n = 13) 2.8 (0.8) 2.8 (0.8) 0.48
Myocardium- LGE sharpness (n = 13) 3 (0.8) 3 (0.8) 0.48
  1. LGE: Late Gadolinium enhancement, n: number, segmental LGE detection: 0= no LGE, 1= ischaemic, 2= patchy, 3= subepicardial, 4= mid wall, 5= RV insertion points.