Skip to main content

Table 3 Inter-study reproducibility for CMR-FT derived LA dynamics in 2- and 4-chamber views

From: Quantification of atrial dynamics using cardiovascular magnetic resonance: inter-study reproducibility

  

Left atrium (2-chamber view)

Left atrium (4-chamber view)

  

Mean difference ± 2 SD

CoV (%)

ICC (95 % CI)

Mean difference ± 2 SD

CoV (%)

ICC (95 % CI)

Atrial function

Strain (%)

      

Reservoir

εs

0.7 ± 7.1

9.2

0.96 (0.89-0.99)

0.3 ± 8.2

17.4

0.84 (0.55-0.95)

Conduit

εe

0.2 ± 6.3

10.9

0.97 (0.92-0.99)

0.3 ± 7.9

21.7

0.82 (0.48-0.94)

Booster pump

εa

0.5 ± 2.2

22.2

0.92 (0.76-0.97)

0.0 ± 3.3

31.4

0.93 (0.80-0.98)

 

Strain Rate (s −1 )

      

Reservoir

SRs

0.0 ± 0.3

9.9

0.96 (0.90-0.99)

0.0 ± 0.4

21.1

0.89 (0.67-0.96)

Conduit

SRe

0.0 ± 0.5

16.6

0.93 (0.80-0.98)

0.3 ± 0.9

32.6

0.45 (0.00-0.80)

Booster pump

SRa

0.1 ± 0.1

24.4

0.91 (0.73-0.97)

0.0 ± 0.5

37.4

0.76 (0.28-0.92)

  1. Inter-study reproducibility for left atrial strain and strain rate parameters in 2- and 4-chamber views as determined by Bland-Altman analysis (mean difference ± 2SD), coefficients of variation (CoV) and intra-class correlation coefficients (ICC).