Skip to main content

Table 3 Variation in volumetric evaluation due to ectopic contractions

From: User-initialized active contour segmentation and golden-angle real-time cardiovascular magnetic resonance enable accurate assessment of LV function in patients with sinus rhythm and arrhythmias

Subject:

End-diastolic volume (mL)

End-systolic volume (mL)

Ejection fraction (%)

 

All

Non-Ectopic

Ectopic

All

Non-Ectopic

Ectopic

All

Non-Ectopic

Ectopic

1

197.5 ± 8.4

231.4 ± 9.9

165.6 ± 7.3

95.1 ± 4.4

84.4 ± 4.4

106.6 ± 4.5

51.9 ± 4.3

63.5 ± 9.2

35.7 ± 9.6

2

133.9 ± 5.7

149.4 ± 5.9

114.8 ± 5.2

76.3 ± 4.2

69.7 ± 3.8

84.9 ± 5.1

43.0 ± 11.4

53.3 ± 8.4

26.0 ± 14.9

3

113.8 ± 6.9

128.3 ± 7.6

88.7 ± 6.2

56.4 ± 4.6

57.9 ± 4.7

54.9 ± 4.5

50.5 ± 8.8

54.9 ± 8.2

38.2 ± 13.5

4

123.0 ± 6.7

130.3 ± 7.3

104.1 ± 5.8

43.1 ± 4.1

44.9 ± 4.5

42.1 ± 2.4

65.0 ± 12.2

65.5 ± 13.4

59.6 ± 9.6