Skip to main content

Table 2 Accuracy and reproducibility of segmental cardiac analysis with 3D-self-navigated CMR

From: Single centre experience of the application of self navigated 3D whole heart cardiovascular magnetic resonance for the assessment of cardiac anatomy in congenital heart disease

N = 105 patients

N with abnormal findings

Agreement Obs 1 vs Gold standard

Agreement Obs 2 vs Gold standard

Agreement Obs 1 vs Obs 2

1. Atrial situs

1

100 %

100 %

100 %

2. Position of the apex

1

100 %

100 %

100 %

3. Atrial segment morphology

11

100 %

100 %

100 %

4. Atrio-ventricular connection

2

99 %

99 %

100 %

5. Ventricular segment morphology

6

100 %

99 %

99 %

6. Ventriculo-arterial connection

18

99 %

98.1 %

99 %

7. Anatomy of the thoracic aorta

25

100 %

100 %

100 %

8. Anatomy of the venous return

16

100 %

100 %

100 %

9. Intracardiac shunts

12

98.1 %

99 %

97.1 %

10. Course of the coronary arteries

4

100 %

98.1 %

98.1 %

Complete segmental anatomy

(Agreement = all 10 elements correctly evaluated)

 

96.2 %

93.3 %

93.3 %

  1. Obs: Observer