Skip to main content

Table 5 Relative likelihood ratios and the numbers of new true positive and false positive cases produced by adding on further components sequentially to stress perfusion imaging in isolation

From: Individual component analysis of the multi-parametric cardiovascular magnetic resonance protocol in the CE-MARC trial

 

Relative LR+

Relative LR-

New true positive cases produced

New false positives cases produced

Perfusion (+LGE)

0.78

0.91

7

11

Perfusion (+function)

0.68

0.89

9

18

Perfusion (+MRA)

0.79

0.76

16

12

Perfusion + LGE (+function)

0.79

0.89

8

14

Perfusion + LGE (+MRA)

0.86

0.74

16

11

Perfusion + function (+MRA)

0.89

0.76

14

10

Perfusion + function (+LGE)

0.91

0.94

4

6

  1. LGE late gadolinium enhancement, LR likelihood ratio, MRA magnetic resonance coronary angiography