Skip to main content

Table 2 Comparison of pre-/post-contrast myocardium and blood T1 times and ECV between diastolic and systolic T1 maps in healthy volunteers

From: Systolic MOLLI T1 mapping with heart-rate-dependent pulse sequence sampling scheme is feasible in patients with atrial fibrillation

 

Diastole

Systole

P value

Overall LV myocardium native T1 times (ms)

1247.73 ± 31.86

1231.06 ± 31.45

<0.01

Overall LV myocardium post-contrast T1 times (ms)

544.94 ± 52.80

563.80 ± 56.89

<0.01

Overall LV pre-contrast blood T1 times (ms)

1832.76 ± 61.76

1784.49 ± 82.02

<0.05

Overall LV post-contrast blood T1 times (ms)

352.87 ± 49.15

365.53 ± 51.70

<0.01

Overall LV ECV (%)

25.11 ± 1.63

24.60 ± 1.58

=0.047

  1. Data are presented in mean ± standard deviation. LV left ventricle, ECV extracellular volume