Skip to main content

Table 6 ROC analysis of first-pass perfusion for detecting microvascular dysfunction between AL-CA patients with impaired systolic function and normal controls

From: Regional myocardial microvascular dysfunction in cardiac amyloid light-chain amyloidosis: assessment with 3T cardiovascular magnetic resonance

 

Cutoff

AUC

Sensitivity (%) (95 % CI)

Specificity (%) (95 % CI)

Basal segment

Upslope

4.1

0.969

92 (83–98)

93 (88–97)

TTM

21.9

0.932

97 (90–100)

76 (68–83)

MaxSI

42

0.852

79 (67–88)

85 (78–90)

Mid-ventricular segment

Upslope

4

0.941

89 (79–96)

90 (84–94)

TTM

21.68

0.941

98 (92–100)

77 (69–83)

MaxSI

36

0.772

61 (48–72)

94 (89–97)

Apical segment

Upslope

4.57

0.906

77(62–88)

94 (87–98)

TTM

23

0.886

95 (85–99)

74 (64–82)

MaxSI

43

0.638

52 (37–68)

77 (68–85)

  1. Notes: AUC = area under the ROC curve. The abbreviations are the same as in Tables 1 and 2