Skip to main content

Table 3 The LV volume measurements between standard cine and CS cine

From: Compressed sensing real-time cine cardiovascular magnetic resonance: accurate assessment of left ventricular function in a single-breath-hold

 

Standard cine (n = 81)

CS cine (n = 81)

p

LVEDV (mL)

121.0 (105.8, 161.7)

122.2 (103, 159)

0.28

LVESV (mL)

48.3 (34.8, 79.1)

50.9 (32.9, 77.8)

0.77

LVSV (mL)

73.5 (63.8, 85.2)

73.4 (63, 83.5)

0.15

LV mass (g)

82.3 (64.7, 101.3)

80.4 (62.1, 99.0)

0.15

LVEF (%)

61.3 (50.5, 68.0)

58.8 (50.7, 67.5)

0.10

  1. The data are presented as the median (first quartile, third quartile)
  2. CS, compressed sensing; LV, left ventricular; LVEDV, left ventricular end diastolic volume; LVEF, left ventricular ejection fraction; LVESV, left ventricular end systolic volume; LVSV, left ventricular stroke volume