Skip to main content

Table 4 Quantitative and statistical analysis results for the comparison of BTI, MPRAGE and CE-MRV

From: Black-blood thrombus imaging (BTI): a contrast-free cardiovascular magnetic resonance approach for the diagnosis of non-acute deep vein thrombosis

 

BTI

reader1/reader2

MPRAGE

reader1/reader2

CE-MRV

reader1/reader2

Diagnostic confidence score, mean ± SD.

3.12 ± 0.39/3.65 ± 0.30

2.52 ± 0.27/2.16 ± 0.22

3.50 ± 0.46/3.69 ± 0.44

True positive, n

50/53

37/40

NA

True negative, n

243/246

240/241

NA

False positive, n

4/1

7/6

NA

False negative, n

7/4

20/17

NA

SE, %

87.7/93.0

64.9/70.2

NA

SP, %

98.4/99.6

97.2/97.6

NA

PPV, %

92.6/98.1

84.1/87.0

NA

NPV, %

97.2/98.4

92.3/93.4

NA

ACC, %

96.4/98.4

91.1/92.4

NA

Diagnostic agreement with CE-MRV, (κ value/p)

(0.88/< 0.001)/(0.95/< 0.001)

(0.68/< 0.001)/(0.73/< 0.001)

NA

Interreader agreement, (κ value/p)

(0.89/<0.001)

(0.64/<0.001)

(0.96/<0.001)

  1. Note: SD Standard Deviation, SE Sensitivity, SP Specificity, PPV Positive Predictive Values, NPV Negative Predictive Values, ACC Accuracy, NA Not Applicable