Skip to main content

Table 2 CMR parameters pre and 6 m post-TAVR according to post-procedure QRS status

From: The impact of trans-catheter aortic valve replacement induced left-bundle branch block on cardiac reverse remodeling

 

nQRS

(n = 24)

LBBB-T

(n = 24)

P Value

Left ventricular ejection fraction

 Pre-procedure

54.1 ± 11.5

56.6 ± 10.5

0.386

 Post-procedure

58.7 ± 9.0

54.4 ± 9.3

0.070

  P Value

0.010

0.092

 

Global longitudinal strain, %

 Pre-procedure

−15.6 ± 3.9

−16.2 ± 4.2

0.638

 Post-procedure

−17.7 ± 2.7

−15.9 ± 3.4

0.053

  P Value

0.009

0.771

 

Indexed left ventricular mass, g/m2

 Pre-intervention

74.3 ± 14.7

73.3 ± 17.4

0.650

 Post-intervention

58.4 ± 12.6

60.0 ± 13.7

0.665

  P Value

<0.001

<0.001

 

Indexed left ventricular end diastolic volume, ml/m2

 Pre-intervention

97.8 ± 22.8

93.4 ± 22.1

0.500

 Post-intervention

90.5 ± 21.0

90.3 ± 21.0

0.968

  P Value

0.051

0.298

 

Indexed left ventricular end systolic volume, ml/m2

 Pre-intervention

46.6 ± 20.4

41.8 ± 17.7

0.458

 Post-intervention

38.7 ± 16.2

42.4 ± 17.8

0.523

  P Value

0.011

0.886

 

Indexed left ventricular stroke volume, ml/m2

 Pre-intervention

51.2 ± 10.3

51.4 ± 10.5

0.945

 Post-intervention

51.8 ± 8.7

47.9 ± 8.5

0.122

  P Value

0.742

0.035

 

Indexed left atrial volume, ml/m2

 Pre-intervention

67.9 ± 19.2

72.9 ± 23.3

0.232

 Post-intervention

60.0 ± 18.2

67.9 ± 23.8

0.199

  P Value

0.002

0.180

 
  1. nQRS narrow QRS post-procedure, LBBB-T new LBBB post-procedure