Skip to main content

Table 3 Summary of correlations of change between visits obtained using continuous and manual measurement methods (Note: F-test employed in all cases. F-value and corresponding critical value were compared in order to determine equivalence of the variances of change between visits obtained manually and continuously. For good concordance between methods we tested whether F < Fcrit [26])

From: Continuous measurement of aortic dimensions in Turner syndrome: a cardiovascular magnetic resonance study

Case

F < Fcrit

Overall Visit 1 to 2

Y

Overall Visit 2 to 3

Y

Overall Visit 1 to 3

Y

Ascending Visit 1 to 2

Y

Ascending Visit 2 to 3

Y

Ascending Visit 1 to 3

Y

Transverse Visit 1 to 2

Y

Transverse Visit 2 to 3

N

Transverse Visit 1 to 3

Y

Descending Visit 1 to 2

N

Descending Visit 2 to 3

Y

Descending Visit 1 to 3

Y