Skip to main content

Table 3 Multiple linear regression analysis of variables for the prediction of left ventricular reverse remodeling

From: Assessment of reverse remodeling predicted by myocardial deformation on tissue tracking in patients with severe aortic stenosis: a cardiovascular magnetic resonance imaging study

  

Estimated beta

standard error

p-value

Model 1

radial strain

1.834

0.839

0.033

circumferential strain

7.527

3.275

0.026

longitudinal global strain

−38.444

11.797

0.002

3D circumferential strain

30.932

12.572

0.017

3D longitudinal global strain

−4.123

6.884

0.55

longitudinal global strain: 3D longitudinal global strain

−2.390

0.796

0.004

3D circumferential strain: 3D longitudinal global strain

2.179

0.840

0.012

Model 2

max velocity of aortic valve

−12.566

4.845

0.012

longitudinal global strain

−3.335

0.849

<0.001

  1. All strain parameters (6 variables) were calculated by a stepwise multiple linear regression analysis, and several multiple linear regression models were performed with strain parameters or baseline parameters; Model 1, adjusting the stepwise selection as considered with interaction; Model 2, including the main effect term adjusting with baseline parameters such as the age, gender, E velocity, e` velocity, max velocity of aortic valve, ejection fraction by Simpson’s method
  2. All strain parameters were measured by cardiovascular magnetic resonance myocardial tissue tracking