Table 2 The Dice metric, mean contour distance (MCD) and Hausdorff distance (HD) between automated segmentation and manual segmentation for short-axis images

From: Automated cardiovascular magnetic resonance image analysis with fully convolutional networks

(a) The full test set (n = 600)

   
 

Dice

MCD (mm)

HD (mm)

LV cavity

0.94 (0.04)

1.04 (0.35)

3.16 (0.98)

LV myocardium

0.88 (0.03)

1.14 (0.40)

3.92 (1.37)

RV cavity

0.90 (0.05)

1.78 (0.70)

7.25 (2.70)

(b) Cases with CVDs (n = 39)

   

LV cavity

0.94 (0.04)

1.19 (0.41)

3.62 (1.14)

LV myocardium

0.87 (0.04)

1.23 (0.40)

4.28 (1.18)

RV cavity

0.90 (0.04)

2.02 (0.88)

8.19 (2.94)

  1. The mean and standard deviation (in parenthesis) are reported
  2. CVD: cardiovascular diseases, LV: left ventricle, RV: right ventricle