Fig. 5 | Journal of Cardiovascular Magnetic Resonance

Fig. 5

From: Comparison of left ventricular strains and torsion derived from feature tracking and DENSE CMR

Fig. 5

Propagated contours and reported feature tracking strains are inconsistent (representative subject). The propagated endocardial contours for frame 1 and frame 30 (the last frame) of a representative subject are shown along with the strains reported by feature tracking. Despite the differences in contour length, which would be measured as strain by the contour-based calculation, the feature tracking software reported zero strain in all segments and, thus, zero slice-wise strain. When deriving strains, the feature tracking software may employ curve-fitting after propagating the contours, which would lead to differences between the reported feature tracking strains and the contour-based strains