Skip to main content

Table 5 Intra- and inter-observer reproducibility for left atrial strain and strain rate measurements derived by fast and FT approach

From: Validation of a rapid semi-automated method to assess left atrial longitudinal phasic strains on cine cardiovascular magnetic resonance imaging

Method

Strain/SR

Intra-observer (n = 20)

Inter-observer (n = 20)

Bias (limits of agreement)

CV, %

Bias (limits of agreement)

CV, %

Fast approach

εs, %

−0.01 (−2.37, 2.34)

3.6

−0.15 (−3.16, 2.86)

4.7

εe, %

−0.15 (−1.81, 1.51)

5.3

0.10 (−1.58, 1.77)

5.3

εa, %

0.14 (−1.76, 2.04)

6.2

−0.25 (−2.93, 2.43)

8.9

SRs, 1/s

0.03 (−0.18, 0.23)

6.5

0.06 (−0.24, 0.35)

9.7

SRe, 1/s

−0.05 (− 0.29, 0.18)

7.9

− 0.03 (− 0.29, 0.23)

8.1

SRa, 1/s

−0.01 (− 0.25, 0.24)

6.4

−0.03 (− 0.38, 0.32)

9.4

FT approach

εs, %

0.16 (−5.39, 5.72)

8.6

0.21 (−5.29, 5.71)

8.5

εe, %

0.24 (−2.54, 3.02)

8.8

−0.17 (−3.18, 2.84)

9.5

εa, %

−0.08 (− 3.01, 2.87)

9.6

0.38 (− 3.26, 4.02)

11.9

SRs, 1/s

0.03 (−0.28, 0.34)

9.5

0.07 (−0.25, 0.39)

10.0

SRe, 1/s

−0.06 (− 0.36, 0.25)

10.3

0.08 (− 0.26, 0.42)

11.4

SRa, 1/s

−0.03 (− 0.44, 0.37)

10.6

− 0.08 (− 0.62, 0.45)

13.9

  1. ε left atrial strain, SR left atrial strain rate, FT feature tracking, CV coefficient of variation