Table 1 Carotid CMR scan parameters

From: Microvasculature and intraplaque hemorrhage in atherosclerotic carotid lesions: a cardiovascular magnetic resonance imaging study

Pulse sequence

3D TOF

3D T1w IR TFE

T2w TSE

Pre- and post-contrast T1w QIR TSE

3D T1w IR TFE (for DCE-CMR)

Acquisition plane

transversal

transversal

transversal

transversal

transversal

TR (ms)

20

9.1

4800

800

11

TE (ms)

5

5.5

49

10

5.7

TI (ms)

–

304

–

282

–

Flip angle (°)

20

15

–

–

35

Number of slices

15

15

15

15

5

Slice thickness (mm)

2

2

2

2

2

FOV (mm)

160 × 160

160 × 128

160 × 160

160 × 160

130 × 130

Acquired matrix

260 × 258

260 × 204

260 × 252

260 × 240

208 × 206

Reconstruction matrix

528 × 528

528 × 528

528 × 528

528 × 528

512 × 512

ECG triggered

No

No

No

No

Yes, end-diastolic

Fat suppression

Yes

Yes

Yes

Yes

No

  1. TOF time of flight, IR TFE inversion recovery turbo field echo, TSE turbo spin echo, QIR TSE quadruple inversion recovery turbo spin echo, TR repetition time, TE echo time, TI inversion time, FOV field of view, ECG electrocardiogram