Skip to main content

Table 6 Reproducibility of manual and automated analyses

From: Fully automated quantification of biventricular volumes and function in cardiovascular magnetic resonance: applicability to clinical routine settings

 

Parameter

Mean Difference (SD of the Diff.)

ICC (95% CI)

CoV (%)

Manual

Intra-observer

LV Mass

−0.3 (3.4)

0.99 (0.97–1.00)

5.3

LV EDV

−3.3 (3.4)

0.99 (0.91–1.00)

4.0

LV ESV

−2.6 (3.0)

0.99 (0.95–1.00)

8.4

LV SV

−0.6 (3.9)

0.97 (0.93–0.99)

8.0

LV EF

1.7 (3.7)

0.98 (0.94–0.99)

6.3

RV EDV

−1.5 (6.7)

0.96 (0.90–0.98)

9.6

RV ESV

1.8 (4.3)

0.95 (0.87–0.98)

14.2

RV SV

−3.5 (6.3)

0.81 (0.49–0.93)

15.6

RV EF

−2.9 (5.1)

0.82 (0.49–0.93)

8.9

Inter-observer

LV Mass

−0.7 (3.3)

0.99 (0.97–1.00)

5.6

LV EDV

−5.6 (5.8)

0.97 (0.74–0.99)

6.7

LV ESV

−6.3 (4.8)

0.97 (0.46–0.99)

12.5

LV SV

0.8 (3.7)

0.97 (0.93–0.99)

7.7

LV EF

5.2 (57.9)

0.94 (0.44–0.98)

8.0

RV EDV

−15.5 (7.8)

0.82 (0.00–0.96)

10.0

RV ESV

−7.3 (5.7)

0.84 (0.00–0.96)

16.4

RV SV

−8.1 (6.9)

0.75 (0.00–0.93)

16.2

RV EF

1.3 (7.2)

0.62 (0.04–0.85)

12.9

Automatic

Intra-observer

LV Mass

0.0 (0.0)

1.00

0.0

LV EDV

0.0 (0.0)

1.00

0.0

LV ESV

0.0 (0.0)

1.00

0.0

LV SV

0.0 (0.0)

1.00

0.0

LV EF

0.0 (0.0)

1.00

0.0

RV EDV

0.0 (0.0)

1.00

0.0

RV ESV

0.0 (0.0)

1.00

0.0

RV SV

0.0 (0.0)

1.00

0.0

RV EF

0.0 (0.0)

1.00

0.0

Inter-observer

LV Mass

0.0 (0.0)

1.00

0.0

LV EDV

0.0 (0.0)

1.00

0.0

LV ESV

0.0 (0.0)

1.00

0.0

LV SV

0.0 (0.0)

1.00

0.0

LV EF

0.0 (0.0)

1.00

0.0

RV EDV

0.0 (0.0)

1.00

0.0

RV ESV

0.0 (0.0)

1.00

0.0

RV SV

0.0 (0.0)

1.00

0.0

RV EF

0.0 (0.0)

1.00

0.0

  1. Biventricular volumes and LV mass were indexed to body surface area. SD: standard deviation. ICC: intraclass correlation coefficient. CoV: coefficient of variation. LV: left ventricular. RV: right ventricular. EDV/ESV end-diastolic/systolic volume. SV: stroke volume. EF: ejection fraction