Skip to main content

Table 1 Peripheral artery flow measurements

From: Dynamic quantitative nonenhanced magnetic resonance angiography of the abdominal aorta and lower extremities using cine fast interrupted steady-state in combination with arterial spin labeling: a feasibility study

Volunteers

1

2

3

4

5

6

7

Calf-Thigh

 2DPC

63.7 cm/s

47.5 cm/s

67.2 cm/s

89.7 cm/s

44.0 cm/s

73.5 cm/s

42.2 cm/s

 cFASL

59.7 cm/s

56.8 cm/s

72 cm/s

102.3 cm/s

60.6 cm/s

76.7 cm/s

45.5 cm/s

Mid-Thigh

 2DPC

73.7 cm/s

64.3 cm/s

88.2 cm/s

101.3 cm/s

71.3 cm/s

124.0 cm/s

77.9 cm/s

 cFASL

89.4 cm/s

63.9 cm/s

94.7 cm/s

106.1 cm/s

72.4 cm/s

136.3 cm/s

81.0 cm/s

Proximal Thigh

 2DPC

84.5 cm/s

65.7 cm/s

74.0 cm/s

84.8 cm/s

68.4 cm/s

123.2 cm/s

a

 cFASL

83.3 cm/s

76.7 cm/s

76.7 cm/s

113.6 cm/s

72.0 cm/s

121.2 cm/s

a

Pelvis

 2DPC

91.6 cm/s

79.4 cm/s

88.6 cm/s

127.2 cm/s

73.6 cm/s

127.4 cm/s

74.2 cm/s

 cFASL

110.8 cm/s

72.0 cm/s

85.2 cm/s

132.1 cm/s

76.7 cm/s

128.8 cm/s

89.5 cm/s

  1. aValues excluded due to technical issue with acquisition of 2DPC at this level
  2. Flow measurements at each level of the lower extremities in cm/s calculated from analysis of 2D phase contrast (PC) and cine fast interrupted steady-state in combination with arterial spin labeling (cFASL) data in seven healthy subjects