Skip to main content

Table 3 Results for diagnostic performance of different measurement approaches

From: Multiparametric cardiovascular magnetic resonance imaging in acute myocarditis: a comparison of different measurement approaches

 

Cut off

AUC

Sensitivity (%)

Specifity (%)

PPV (%)

NPV (%)

Accuracy (%)

Native T1 (ms)

 Global

> 980

0.903

85

90

93

79

87

 mSAX

> 985

0.850

76

93

95

72

83

 ConSept

> 999

0.783

65

97

97

62

77

 Remote

> 980

0.841

73

90

91

69

80

ECV (%)

 Global

> 31

0.731

47

88

87

49

62

 mSAX

> 28

0.717

67

72

81

56

69

 ConSept

> 27

0.633

70

52

71

50

63

 Remote

> 29

0.685

64

68

76

55

66

T2 (ms)

 Global

> 54

0.847

80

87

90

74

82

 mSAX

> 53

0.831

78

87

90

72

81

 ConSept

> 53

0.820

80

87

90

74

82

 Remote

> 54

0.799

74

87

89

70

79

  1. ECV extracellular volume fraction, mSAX midventricular short axis, NPV negative predictive value, PPV positive predictive value