Skip to main content

Table 3 Distribution of scores for image quality, artifacts, and diagnostic confidence of both readers combined for breath-hold and free-breathing LGE in absolute and relative values

From: Clinical application of free-breathing 3D whole heart late gadolinium enhancement cardiovascular magnetic resonance with high isotropic spatial resolution using Compressed SENSE

Criterion

Technique

Non-diagnostic

Poor

Fair

Good

Excellent

Good + excellent

Image

Breath-hold

–

7 (5.0%)

11 (7.9%)

45 (32.1%)

77 (55.0%)

122 (87.1%)

quality

Free-breathing

–

7 (5.0%)

21 (15.0%)

61 (43.6%)

51 (36.4%)

112 (80.0%)

Criterion

Technique

Non-diagnostic

High impact

Moderate impact

Low impact

None

Low impact + none

Artifacts

Breath-hold

–

5 (3.6%)

21 (15.0%)

42 (30.0%)

72 (51.4%)

114 (81.4%)

 

Free-breathing

–

11 (7.9%)

19 (13.6%)

63 (45.0%)

47 (33.6%)

110 (78.6%)

Criterion

Technique

Non-diagnostic

Low

Fair

Good

High

Good + high

Diagnostic

Breath-hold

–

6 (4.3%)

7 (5.0%)

40 (28.6%)

87 (62.1%)

127 (90.7%)

confidence

Free-breathing

–

4 (2.9%)

21 (15.0%)

33 (23.6%)

82 (58.6%)

115 (82.1%)