Skip to main content

Table 65 Left ventricular global peak circumferential strain using tagging

From: Reference ranges (“normal values”) for cardiovascular magnetic resonance (CMR) in adults and children: 2020 update

Parameter

n

Meanp

SDp

LL–ULa

Circumferential strain (%)

204

 − 20.1

3.0

 − 26.0 to − 14.2

  1. Pooled weighted values from references [182, 183]
  2. n number of study subjects included in the weighted mean values, meanp pooled weighted mean, SDp pooled standard deviation, LL lower limit, UL upper limit
  3. aCalculated as meanp ± 2*SDp