Skip to main content

Table 4 Bland–Altman analysis of all PV ostial diameters and areas on each non-contrast CMRA sequence compared to CTA for both readers

From: Radial-based acquisition strategies for pre-procedural non-contrast cardiovascular magnetic resonance angiography of the pulmonary veins

  

BH-2D

BH-SOS

FB-NS-SOS

CT mean value

Dmax (mm)

Reader 1

0.81 (− 4.52, 6.14)

0.55 (− 3.93, 5.04)

0.95 (− 3.88, 5.78)

23.22

Reader 2

0.74 (− 5.10, 6.60)

0.23 (− 4.01, 4.47)

0.58 (− 2.87, 4.03)

23.37

Dmin (mm)

Reader 1

0.47 (− 5.49, 6.44)

0.33 (− 4.30, 4.97)

− 0.13 (− 3.87, 3.62)

17.06

Reader 2

0.89 (− 4.91, 6.68)

0.35 (− 4.22, 4.92)

0.10 (− 2.65, 2.85)

17.34

Area (mm2)

Reader 1

20.69 (− 119.77, 161.16)

6.95 (− 94.58, 108.48)

13.10 (− 82.88, 109.09)

303.93

Reader 2

25.07 (− 99.89, 150.04)

8.50 (− 81.04, 98.04)

8.83 (− 64.02, 81.69)

313.67

  1. Data are presented as mean difference (95% limits of agreement). The smallest mean differences with respect to CTA are shown in bold. The mean values for PV ostial diameters and area by CTA are provided in the right-most column