Skip to main content

Table 2 Typical CMR imaging parameters for ex vivo scans

From: Native contrast visualization and tissue characterization of myocardial radiofrequency ablation and acetic acid chemoablation lesions at 0.55 T

Ex vivo scan

Imaging technique

Acquired / reconstructed spatial resolution (mm3)

TR / TE (ms)

Flip angle (deg)

Receiver bandwidth (Hz/pixel)

Acquisition time (h)

Acceleration factor (GRAPPA)

Other parameters

T1-W 3D -Mid Res

SPGR

0.5 isotropic / 0.5 isotropic

25.0 / 5.23

40

130

 ~ 2

None

6 Averages

T1-W 3D -High Res

SPGR

0.25 × 0.25 × 0.5 / 0. 25 Isotropic

25.0 / 5.23

40

130

10–12

None

24–30 Averages

DESPOT

T1 Mapping

SPGR

1.0 isotropic / 1.0 isotropic

30 / 4.72

11°–56°

130

1.35

None

10 Flip angles

5°steps

  1. SPGR RF-spoiled gradient echo, DESPOT drive equilibrium single pulse observation of T1, GRAPPA generalized autocalibrating partially parallel imaging