Table 4 Subgroup correlation analysis of repaired retralogy of Fallot (rTOF) patients with exercise stress test results (n = 19)

From: Moving beyond size: vorticity and energy loss are correlated with right ventricular dysfunction and exercise intolerance in repaired Tetralogy of Fallot

 

VO2-max

p

% Predicted VO2-max

p

Conventional

 RVEF (%)

− 0.291

ns

0.259

ns

 PR%

− 0.192

ns

− 0.267

ns

 RVEDVI (mL/m2)

0.252

ns

− 0.046

ns

 RVESVI (mL/m2)

0.313

ns

− 0.166

ns

 QRS (ms)

− 0.235

ns

− 0.069

ns

Vorticity

 ωRVOT-Diastole

− 0.434

ns

− 0.5497

0.016

 RVOT-VQ (ωRVOT-Diastole/ωRVOT-Systole)

− 0.587

0.008

− 0.678

0.001

 RV-DVQ (ωRVOT-Diastole/ωRV Inflow-Diastole)

− 0.266

Ns

− 0.641

0.003

Energy Loss

 VELRVOT-Diastole

− 0.497

0.03

− 0.375

ns

 RVOT-EQ (VELRVOT-Diastole/VELRVOT-Systole)

− 0.617

0.005

− 0.6902

0.001