Table 3 Automated clinical metric accuracy of mitral valve derived parameters

From: MVnet: automated time-resolved tracking of the mitral valve plane in CMR long-axis cine images with residual neural networks: a multi-center, multi-vendor study

Clinical agreement n subjects Manual measures Automated measures Error measures ICC (CI 95%)
MAPSE (mm) 143 12.3 ± 4.0 12.1 ± 3.9 −0.2 ± 1.3 0.94 (0.92–0.96)
LV e’ (cm/s) 96 6.6 ± 4.1 6.6 ± 3.7 0.0 ± 1.5 0.93 (0.90–0.95)
  1. The mean ± standard deviation are reported for manual and automated measures and their error, evaluated on the mixed test set with the proposed model (\({{\text{MVnet}}_{\text{Mixed}}}\)). MAPSE mitral annular plane systolic excursion, LV left ventricle, ICC intra-class correlation coefficient, CI confidence interval