Table 9 MAE between manually and automatically generated shape models in the test set based on projection distance

From: A deep learning approach for fully automated cardiac shape modeling in tetralogy of Fallot

MAE (mm)

ED

ES

Global

1.9 ± 0.5

2.1 ± 0.7

Region

  

 LV Endocardium

1.6 ± 0.7

1.8 ± 1.0

 RV Endocardium

1.8 ± 0.5

2.1 ± 0.5

 Septum

1.3 ± 0.4

1.4 ± 0.5

 Epicardium

2.2 ± 0.8

2.5 ± 1.0

 MV

4.6 ± 0.5

5.6 ± 0.7

 AV

5.2 ± 0.1

5.4 ± 0.3

 TV

3.6 ± 0.6

3.9 ± 0.5

 PV

3.1 ± 0.3

3.0 ± 0.3

  1. Numerical data are reported as mean ± standard deviation. MAE mean absolute error, ED end-diastole, ES end-systole, LV left ventricular, RV right ventricular, MV mitral valve, AV aortic valve, TV tricuspid valve, PV pulmonary valve