Splenic switch-off, a potential novel marker of lack of adenosine response: relationship to heart rate response and demographic factors
Journal of Cardiovascular Magnetic Resonance volume 17, Article number: P92 (2015)
Background
Haemodynamic response is currently used as a marker of adenosine response during cardiovascular magnetic resonance (CMR) adenosine stress perfusion. However, the sensitivity of these scans is reduced by false negatives, some of which are due to inadequate response to adenosine. Blunted adenosine response can be due to a variety of environmental and pharmacological factors, including recent caffeine intake. Splenic blood flow falls in response to adenosine, splenic switch-off (SSO), and may provide a simple visual marker of adequate stress. The aim of this study was to compare the prevalence SSO to haemodynamic response, and assess its relationship to demographic factors.
Methods
We examined 503 negative CMR adenosine perfusion scans for SSO by visual assessment. As per local protocol, patients were instructed to avoid caffeine 12 hours before the scan. All patients initially received the standard adenosine protocol (140 mcg/kg/min for at least 3 minutes). If the haemodynamic response was inadequate (HR increase < 10 bpm or SBP decrease < 10 mmHg) then the infusion rate was increased up to a maximum of 210 mcg/kg/min following which an intravenous bolus of 0.05mmol/kg of Gadoteric acid was administered (stress); the second bolus was administered at rest. For the purpose of this study, we considered heart rate increase of 10bpm as a positive haemodynamic response. A multivariate regression model was built using stepwise selection, and covariates were included if they satisfied p<0.05.
Results
Six scans (1.2%) were excluded due to poor quality and 5 (1%) had no visible spleen. 53 of the remaining 492 scans (11.0%) had no SSO.
Age and gender did not differ significantly between those with or without SSO. People without SSO were more likely to be white (p<0.001).
Haemodynamic response was associated with SSO (OR=2.43, p<0.01). White ethnicity reduced odds of SSO (OR= 0.25). However, a significant proportion of people did not have SSO, but had a positive haemodynamic response (66.0%). Similarly, many people who had SSO did not have a haemodynamic response (18.0%) (table 2).
Conclusions
SSO is associated with positive haemodynamic response and is less frequently seen in people of white ethnicity. If SSO is a good indicator of adequate adenosine stress, as many as 23% of patients could have a misclassified response by current haemodynamic methods. The diagnostic accuracy of SSO could be compared against coronary angiography. However, the prognostic value of the presence or absence of SSO can only be inferred after the acquisition of outcome data.
Funding
AL recieved a Rod Flower scholarship from Barts and the London School of Medicine and Dentistry.
Author information
Authors and Affiliations
Rights and permissions
This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
About this article
Cite this article
Lighton, A., Koulouroudias, M., Zemrak, F. et al. Splenic switch-off, a potential novel marker of lack of adenosine response: relationship to heart rate response and demographic factors. J Cardiovasc Magn Reson 17 (Suppl 1), P92 (2015). https://doi.org/10.1186/1532-429X-17-S1-P92
Published:
DOI: https://doi.org/10.1186/1532-429X-17-S1-P92