1067 MR assessment of long term pulmonary arterial morphology following surgical ligation of systemic to pulmonary arterial shunts: visualising a potential risk

Introduction

Formation of a Blalock-Taussig (BT) shunt to establish a secure source of pulmonary blood flow is the first stage of palliation for a significant proportion of children born with congenital heart disease. With further palliative or corrective surgery, ligation rather than surgical division of a previously-formed BT shunt has been the preferred surgical strategy. We hypothesise that ligation rather than division of a shunt carries a risk of iatrogenic vascular constraint with respect to the pulmonary arteries, producing distortion with somatic growth.

Purpose

As an initial approach to assess this, using Cardiac Magnetic Resonance (MR) Imaging, we studied branch pulmonary artery (PA) anatomy and pulmonary artery blood flow in a homogenous cohort of patients with similar primary cardiac anatomy, haemodynamics and surgical course.

Methods

We retrospectively reviewed cardiac magnetic resonance (MR) imaging studies and hospital records of all patients with Tetralogy of Fallot who had undergone surgical takedown of a Blalock-Taussig Shunt between January 1987 and January 1992, (a 15–20 year period of follow-up from the present date). Non-breath-hold, FLASH gradient echo phase-contrast MR sequences was used to measure flow in the pulmonary trunk and the non-stenosed PA's. Anatomical features were assessed with MR angiographic and bSSFP images. MR scans were reviewed by experienced personnel blinded to clinical details and the surgical history for the presence of: 1) angiographic PA distortion (tenting/kinking), 2) presence of PA hypoplasia, 3) abnormalities of distal pulmonary vascular arborisation.

Results

Forty-five patients underwent corrective surgery for Tetralogy of Fallot during the study period, had been subsequently studied with MR imaging, and had available operative records. Of this group, 30 patients underwent primary repair, and 15 patients were known to have had a previous BT shunt that was taken down at the time of complete repair. The median time from the takedown of the BT shunt to assessment by MR imaging was 16.0 years (range to 10.4 to 19.2 years). Twelve patients had their BT shunts ligated and one patient had their shunt surgically divided. The surgical method was not specified for 2 patients. Asymmetry of branch PA anatomy and flow was evident in every patient, and unilateral abnormalities correlated with the side of the previous BT shunt.

Specific tenting and kinking related to the position of the BT shunt was evident in 5/12 patients after undergoing BT ligation. Absence of this kinking was noted in the single patient undergoing surgical division of the shunt.

Conclusion

Surgical placement of a BT has long been associated with PA distortion. This limited review suggests that simple ligation at the time of take-down of this shunt, may be associated with accentuated distortion of PA morphology and growth, but is not consistently so. Further assessment of this phenomenon is needed, with particular attention to the cohort of patients with functionally univentricular hearts and Fontan-type circulation, who require low pulmonary pressures for effective pulmonary flow.

Author information

Authors and Affiliations

Authors

Rights and permissions

Open Access This article is published under license to BioMed Central Ltd. This is an Open Access article is distributed under the terms of the Creative Commons Attribution 2.0 International License (https://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Sridharan, S., de Leval, M., Hughes, M. et al. 1067 MR assessment of long term pulmonary arterial morphology following surgical ligation of systemic to pulmonary arterial shunts: visualising a potential risk. J Cardiovasc Magn Reson 10 (Suppl 1), A192 (2008). https://doi.org/10.1186/1532-429X-10-S1-A192

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/1532-429X-10-S1-A192

Keywords